European Assessment Document

    EAD 330747-00-0601 - Fasteners for use in concrete for redundant non-structural systems

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 330747-00-0601 is the EOTA European Assessment Document for fasteners for use in concrete for redundant non-structural systems. Amstelfy Technical Solutions tests ceiling and services fasteners used in groups against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): installation and functioning, characteristic resistance and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 330747-00-0601 covers post-installed fasteners, typically small mechanical anchors, ceiling anchors and concrete screws, used in numbers to hold non-structural systems: suspended ceilings, cable trays, pipework, ducts and similar installations in which several fixing points share the load. Redundancy is the premise: if one fastener fails, the adjacent fixings take its load without the system falling, so the consequences of a single failure are limited. In exchange the EAD requires conditions on the system, among them a minimum number of fixing points and a cap on the design load per fixing point, and allows a shorter test programme than EAD 330232. The assessment establishes one characteristic resistance FRk valid for tension, shear and oblique loading in cracked and uncracked concrete, the installation parameters, spacing and edge distances, functioning under crack movement and durability.

    Assessment programme

    Production fasteners are installed by the laboratory in concrete slabs of the strength range claimed, with the specified drill bit, hole depth and setting method. Reference tension tests are made in cracked concrete, with the crack width prescribed by the EAD, and in uncracked concrete where that use is claimed; shear tests are added when a shear-governed value is to be checked. Functioning tests cover installation safety (hole tolerance, reduced setting energy or torque), crack-width cycling under a sustained load and repeated loading. Series in low- and high-strength concrete bracket the range; a sustained-load test and the durability assessment of the coating or steel grade complete the programme. Fire resistance can be added where the fastener is to carry services in fire compartments.

    What the report states

    The report gives per size the ultimate loads, displacements and failure modes for every series, the 5 % fractiles and the ratios of functioning to reference series. The TAB derives the single characteristic resistance FRk, the concrete strengths and member thicknesses covered, spacing and edge distances, installation parameters and, where tested, fire resistance values, and states the redundancy conditions the designer must satisfy.

    Where the result is required

    Fasteners under this EAD hold the installations of buildings and tunnels: ceilings, cable trays, pipe hangers, ventilation ducts, sprinkler branch lines and lighting, where the fixing is non-structural and distributed over several points. The ETA gives the data for verification by the redundancy rules and the product is CE marked under the AVCP system stated in the EAD. Single fixings or elements whose failure would be structural require an assessment under EAD 330232 or EAD 330499, and driven nails for the same purpose fall under EAD 330083.

    What we assess

    • installation and functioning
    • characteristic resistance
    • durability

    Products covered

    • ceiling and services fasteners used in groups

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    The element must be fixed at several points so that failure of one fastener shifts its load to its neighbours without collapse of the element, and the design load per fixing point must stay below the limit given in the EAD and repeated in the ETA. Suspended ceilings and cable-tray runs typically qualify; a single bracket carrying a heavy unit does not.

    Because the loads are small and redistributed, the EAD evaluates all series against a common criterion and the TAB states one FRk that applies to tension, shear and any angle between them, in cracked and uncracked concrete. The designer does not run the separate concrete-cone, pull-out and steel checks of EN 1992-4; the ETA value and the redundancy conditions replace them.

    Yes. A fastener assessed for structural use already covers the conditions of this EAD, and its resistances can be used for redundant systems with EN 1992-4. The reverse does not hold: a fastener with only an EAD 330747 ETA is restricted to redundant non-structural systems and to the load limit per fixing point stated in its ETA.

    Related standards