US qualification standard
ICC-ES AC232 - Acceptance criteria for anchor channels in concrete elements
In short
ICC-ES AC232 - Acceptance criteria for anchor channels in concrete elements. Amstelfy's laboratory in Amstelveen performs this US qualification protocol for anchor channels: test methods referenced in Annex A. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.
What ICC-ES AC232 determines
ICC-ES AC232 covers cast-in anchor channels with channel bolts, a product that ACI 318 Chapter 17 does not address directly. The criteria therefore do two things. They set out in Annex A the test programme that qualifies the channel profile, the anchors and their connection to the channel, the channel lips and the channel bolts in tension, in shear perpendicular to the channel and, for serrated channels, in shear along the channel, in uncracked and cracked concrete and under simulated seismic loading. And they provide the design provisions that an engineer uses with the ESR values, written in the format of ACI 318 and derived from the same mechanical models as the European method for anchor channels, including the concrete failure modes that are calculated rather than tested.
Specimens, conditioning and procedure
Channels are cast into test members at the production anchor spacing and tested with the bolt types claimed. Tension series load bolts over an anchor and between anchors, isolating anchor, connection and lip-flexure failure, and bolt-only series establish the bolt strength. Perpendicular shear series load the lips or the bolt; longitudinal shear series on serrated channels record load against slip. Tests in cracked members and in low- and high-strength concrete confirm the concrete factors, and seismic qualification adds cyclic tension and shear with crack cycling. Procedures follow ASTM E488 as modified by Annex A, with load and displacement recorded to failure and failure surfaces documented. Material tests on channel steel and bolts and the corrosion-protection specification accompany the structural tests.
What the report states
The report presents each Annex A series with loads, displacements, failure modes and 5 % fractiles, and the characteristic steel strengths derived for anchor, connection, lips, bolt, channel bending and longitudinal shear, plus the concrete-related factors. The ESR then lists these as nominal strengths with strength-reduction factors, the embedment, spacing and edge requirements and the installation parameters for design under its own provisions.
Where the result is required
AC232 evaluation reports are required for anchor channels in US curtain-wall, precast facade, elevator, tunnel and transit projects designed under the IBC. The criteria mirror EAD 330008 closely enough that a manufacturer with an ETA can plan a combined programme, although crack widths, loading protocols and statistical evaluation differ and the series are reported separately for each route. Test methods follow ASTM E488 with the modifications of Annex A.
What we assess
- test methods referenced in Annex A
Products covered
- anchor channels
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 330232-00-0601 - Mechanical fasteners for use in concrete
- EAD 330499-00-0601 - Bonded fasteners for use in concrete
- EAD 330087-01-0601 - Systems for post-installed rebar connections with mortar
- EAD 330008-04-0601 - Anchor channels
- EAD 330011-00-0601 - Adjustable concrete screws
- EAD 330076-00-0604 - Metal injection anchors for use in masonry
- EAD 330083-02-0601 - Power-actuated fasteners for multiple use in concrete for non-structural applications
- EAD 330084-00-0601 - Steel plate with cast-in anchors