    ISO 4892-3 - Plastics - methods of exposure to laboratory light sources - fluorescent UV lamps. Amstelfy's laboratory determines UV ageing of plastics, coatings, membranes, composites according to ISO 4892-3 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What ISO 4892-3 determines

    ISO 4892-3 describes how plastics are exposed in apparatus with fluorescent UV lamps to simulate the damaging short-wavelength part of sunlight together with moisture. Lamp types are defined by their spectral output: UVA-340 lamps reproduce the solar spectrum below about 360 nm, UVA-351 the daylight behind window glass, and UVB-313 lamps emit shorter wavelengths that accelerate degradation but can produce effects not seen outdoors. Exposure runs in cycles of UV at controlled irradiance and black-panel temperature followed by dark condensation or water spray. The result is not a property but a conditioning: specimens are compared with unexposed references for colour, gloss, cracking or retained mechanical properties after a stated radiant exposure or time. The method is the ISO counterpart of ASTM G154, and the general requirements are given in ISO 4892-1.

    Specimens, conditioning and procedure

    Flat specimens, plates or tensile bars, are mounted in the specimen racks with the exposed face towards the lamps; reference specimens are stored in the dark. The client selects the lamp type, the irradiance, the cycle and the duration, or a product standard prescribes them. The most used cycle alternates 8 h of UV with UVA-340 lamps at 0.76 W/(m²·nm) at 340 nm and a black-panel temperature of 60 °C with 4 h of condensation at 50 °C. Irradiance is controlled by sensors and lamp rotation, and temperature by the black-panel thermometer. Specimens are repositioned periodically, and withdrawn at intervals for property measurement when a degradation curve is wanted rather than a single end point.

    What the report states

    The report records lamp type, irradiance, cycle, black-panel temperature, total exposure time and radiant exposure, specimen position and the evaluation performed: colour difference, gloss retention, visual rating of chalking or cracking, or retained tensile or flexural properties relative to unexposed controls, with the test method used for each. Results are specific to the cycle and cannot be converted to years of outdoor life.

    Where the result is required

    Fluorescent UV exposure is specified in product standards and EADs for plastic components that see sunlight before or after installation: roofing underlays and membranes, ETICS and façade components, FRP strengthening systems, geosynthetics, plastic anchors and coatings. EN 1297 for waterproofing sheets and EN 12224 for geotextiles are related artificial-weathering methods; where a specification names ASTM G154 the same apparatus runs the US cycles. The UV-dominated spectrum makes the method severe for surface properties and less representative for colour change behind glass.

    What we assess

    • UV ageing

    Products covered

    • plastics, coatings, membranes, composites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    UVA-340 lamps match sunlight in the critical short-wave UV and give results that rank materials like outdoor exposure. UVB-313 lamps age faster but include wavelengths absent from sunlight and can cause unrealistic failure mechanisms, so they suit quality control of a known material rather than comparison of different polymers. The specification should state the lamp.

    There is no fixed conversion. Acceleration depends on the polymer, the stabiliser package, the property measured and the outdoor climate. The standard reports radiant exposure and cycle only; a correlation can be built for a given product by comparing with outdoor data, which the report supports by listing all exposure parameters.

    Whatever the product specification requires: colour and gloss for appearance, visual rating of cracking and chalking for coatings, and tensile strength or elongation to EN ISO 527 for films, membranes and composites. Specimens for mechanical tests are exposed as finished test pieces so that the exposed face is the tensile face.