US qualification standard

    ASTM G154 - Standard practice for operating fluorescent ultraviolet (UV) lamp apparatus for exposure of nonmetallic materials

    Testing · NAC-037-TL

    In short

    ASTM G154 - Standard practice for operating fluorescent ultraviolet (UV) lamp apparatus for exposure of nonmetallic materials. Amstelfy's laboratory in Amstelveen performs this ASTM method for plastics, coatings, membranes, composites: UV ageing. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ASTM G154 determines

    ASTM G154 is the practice under which fluorescent UV lamp apparatus is operated to expose nonmetallic materials to UV, heat and moisture; it specifies the apparatus, lamps, calibration and operating procedure, while the exposure cycle and the evaluation come from the material specification that invokes it, with reference cycles listed in its appendix. UVA-340 lamps simulate the short-wave end of sunlight; UVB-313 lamps age faster but less realistically. Moisture is supplied as condensation on the cooled specimen back or as water spray. The practice is written with ASTM G151 for general requirements and is the US counterpart of ISO 4892-3, with different irradiance set points and black-panel definitions. Results feed US product specifications and ICC-ES acceptance criteria that require conditioning before property retests.

    Specimens, conditioning and procedure

    Specimens are mounted in holders with the test face towards the lamps and the back exposed to the condensation chamber. The cycle is taken from the specification or chosen from the appendix of the practice; cycle 1 uses UVA-340 lamps at 0.89 W/(m²·nm) at 340 nm for 8 h at a black-panel temperature of 60 °C followed by 4 h of condensation at 50 °C. Irradiance is controlled with calibrated sensors, lamps are replaced on schedule, and specimens are repositioned to even out exposure. Exposure is run to the specified hours or radiant exposure, with intermediate withdrawals when a trend is required. Controls are retained unexposed, and evaluation follows the ASTM test methods named by the specification.

    What the report states

    The report gives lamp type, irradiance and control wavelength, cycle, black-panel thermometer type and set points, total hours and radiant exposure, specimen positions and the post-exposure evaluation: colour and gloss change, visual ratings, or retained tensile, flexural or adhesion properties relative to controls, with the ASTM methods used. Exposure hours are not convertible to outdoor years and the report says so.

    Where the result is required

    US specifications for roofing membranes, coatings, geosynthetics, plastic lumber and FRP products call up this practice, and ICC-ES evaluation programmes for FRP composite systems and polymer components use it for UV conditioning before mechanical retesting. European manufacturers preparing an ESR run the ASTM cycles alongside the ISO 4892-3 exposure their EAD programme requires, often in the same apparatus, since the lamps are identical and only the set points differ.

    What we assess

    • UV ageing

    Products covered

    • plastics, coatings, membranes, composites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The one named in the product specification or acceptance criteria; when none is named, cycle 1 with UVA-340 lamps is the usual default for outdoor plastics, and a UVB-313 cycle is used where a specification carries over from older practice. The report always states the cycle, because results from different cycles are not comparable.

    Apparatus and lamps are the same. The practices differ in reference irradiance levels, in the definition of the black-panel thermometer, in how cycles are tabulated and in reporting conventions. A laboratory can run either; the client specifies which document the exposure must comply with so that the report matches the specification.

    Yes, provided all specimens fit the holders and the cycle is the same. Specimens of different thickness reach different temperatures under the lamps and in condensation, so mixed loads are placed so that the black-panel sensor represents the specimens of interest, and the arrangement is recorded.

    Related standards

    All Plastics, composites & metals - material test methods testing