Test method

    ISO 4892-2 – Xenon arc weathering test

    Plastics - methods of exposure to laboratory light sources - xenon-arc lamps

    Testing · NAC-037-TL

    In short

    ISO 4892-2 - Plastics - methods of exposure to laboratory light sources - xenon-arc lamps. Amstelfy's laboratory determines xenon-arc ageing of plastics, coatings, membranes, composites according to ISO 4892-2 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What ISO 4892-2 determines

    ISO 4892-2 specifies exposure of plastics to filtered xenon-arc radiation, which reproduces the whole solar spectrum from UV through visible to infrared more closely than any other laboratory source. Filters set the spectrum: daylight filters for outdoor exposure (method A) and window-glass filters for indoor exposure behind glazing (method B). Light periods at controlled irradiance and black-standard temperature alternate with water spray or dark periods, and relative humidity is controlled, so that photo-oxidation, hydrolysis, thermal and moisture cycling act together. As with all accelerated weathering, the outcome is a change in properties relative to unexposed specimens after a stated radiant exposure, not a service life. The general requirements for apparatus, calibration and reporting are in ISO 4892-1; ASTM G155 is the US counterpart.

    Specimens, conditioning and procedure

    Specimens are mounted in the rotating rack or flat tray of the apparatus with reference specimens kept in the dark. The client or product standard selects method A or B, the irradiance, the cycle and the exposure. The most common outdoor cycle runs 102 min of light followed by 18 min of light with water spray on the front face, at an irradiance of 0.51 W/(m²·nm) at 340 nm and a black-standard temperature of 65 °C; humidity-controlled and dark-cycle variants are tabulated in the standard. Irradiance is controlled with a calibrated sensor, lamps and filters are replaced on schedule, and specimens are rotated between positions. Specimens are withdrawn at set radiant exposures for measurement.

    What the report states

    The report states method, filter type, irradiance and control wavelength, cycle, black-standard and chamber temperatures, humidity, duration and radiant exposure, together with the evaluation after exposure: colour and gloss change, visual rating, or retained mechanical properties compared with unexposed controls using the relevant test standard. The uncertainty of the irradiance control and the specimen positions are documented so that the exposure can be reproduced.

    Where the result is required

    Xenon-arc exposure is prescribed where colour, gloss and full-spectrum effects matter: pigmented façade and roofing products, coatings, glazing sealants, plastic profiles, geosynthetics and FRP strengthening systems whose UV durability is assessed under the EADs. EN 1297 for roofing sheets and EN 12224 for geotextiles are related procedures; ISO 4892-3 is the fluorescent-UV alternative with a narrower spectrum and simpler apparatus. Manufacturers exporting to North America usually run the ASTM G155 cycles on the same apparatus.

    What we assess

    • xenon-arc ageing

    Products covered

    • plastics, coatings, membranes, composites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Method A with daylight filters simulates outdoor exposure, including water spray; method B with window-glass filters removes the short-wave UV absorbed by glass and is used for interior products such as flooring, furniture surfaces and products behind glazing. Choosing the wrong method gives either unrealistic failures or too mild an exposure.

    It is the temperature of an insulated black reference panel in the specimen plane, representing the hottest a dark specimen can get under the lamp. ISO cycles control it rather than the air temperature because surface temperature drives thermal ageing. ASTM cycles use an uninsulated black panel, which reads a few degrees lower.

    Flat specimens up to the holder size of the apparatus, typically tensile bars, plaques or coated panels; thicker products are cut to fit and their exposed face recorded. Enough specimens are mounted for each withdrawal interval plus unexposed controls, since mechanical evaluation destroys them.

    Related standards

    All Plastics, composites & metals - material test methods testing