US qualification standard

    ASTM G155 – Xenon arc weathering test

    Standard practice for operating xenon arc lamp apparatus for exposure of nonmetallic materials

    Testing · NAC-037-TL

    In short

    ASTM G155 - Standard practice for operating xenon arc lamp apparatus for exposure of nonmetallic materials. Amstelfy's laboratory in Amstelveen performs this ASTM method for plastics, coatings, membranes, composites: xenon-arc ageing. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ASTM G155 determines

    ASTM G155 governs the operation of xenon-arc apparatus for exposing nonmetallic materials to simulated sunlight, heat and moisture. The xenon lamp with daylight filters reproduces the full solar spectrum, and with window-glass filters the spectrum indoors behind glazing; cycles combine light at a controlled irradiance and black-panel temperature with water spray, dark periods and humidity control. Like G154 it is a practice: it fixes apparatus, calibration and procedure and lists reference cycles in its appendix, while the material specification selects the cycle, duration and evaluation. The general requirements are in ASTM G151, and the ISO counterpart is ISO 4892-2. US specifications for roofing, coatings, sealants, textiles and plastics cite it to show colour stability and retained properties after exposure.

    Specimens, conditioning and procedure

    Specimens are mounted in the rotating drum or flat array with the test face towards the lamp; controls are stored in the dark. The cycle is taken from the specification; the most used daylight-filter cycle runs 102 min of light and 18 min of light with water spray at 0.35 W/(m²·nm) at 340 nm and a black-panel temperature of 63 °C, with higher-irradiance variants available. Irradiance is controlled with a calibrated sensor at the chosen wavelength, lamps and filters are replaced on schedule and specimens are repositioned at intervals. Exposure is expressed in hours or in radiant exposure, and specimens are withdrawn at the specified points for property measurement by the ASTM test methods named in the specification.

    What the report states

    Results are expressed as a change relative to the dark-stored controls: colour difference and gloss retention for appearance, chalking or cracking ratings for coatings, or the percentage of tensile, flexural or adhesion property retained, each measured by the ASTM method the specification names. The exposure itself is documented by filter type, irradiance and control wavelength, cycle, black-panel conditions, elapsed hours and cumulative radiant exposure in kJ/m², so that another laboratory can reproduce it.

    Where the result is required

    ASTM specifications for single-ply roofing membranes, sealants, architectural coatings and plastic products require xenon exposure by this practice, and ICC-ES acceptance criteria for roofing and composite products reference it for durability conditioning. European producers entering the US market run G155 cycles on the same apparatus used for ISO 4892-2, and need both exposures documented separately because the irradiance and black-panel conventions differ.

    What we assess

    • xenon-arc ageing

    Products covered

    • plastics, coatings, membranes, composites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The physics is the same: filtered xenon light, water spray and controlled temperature. The documents differ in reference irradiance values, in using an uninsulated black panel versus the insulated black standard, and in the cycle tables. A specification that cites one cannot be satisfied by a report written against the other without stating the deviations.

    The irradiance sets how much light energy reaches the specimen per hour and therefore how many hours are needed for a given radiant exposure; higher levels shorten the test but raise the surface temperature. The specification fixes the level, and the report states it with the control wavelength.

    Small parts and profile sections can be mounted in flat trays if the surface of interest faces the lamp at the specified distance; large or curved parts are cut to representative flat specimens. The exposure is only valid for the surface that received the controlled irradiance.