Test method

    EN 1609 – Short-term water absorption test

    Thermal insulating products - short term water absorption by partial immersion

    Testing · NAC-037-TL

    In short

    EN 1609 - Thermal insulating products - short term water absorption by partial immersion. Amstelfy's laboratory determines short-term water absorption of thermal insulation products (MW, EPS, XPS, PIR, PUR, wood fibre) and building materials according to EN 1609 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1609 determines

    EN 1609 quantifies the water an insulation product takes up through one face during a short wetting, the situation of rain on a stored or freshly installed board or of water standing on a flat roof. A specimen is placed with its lower face a short distance below the surface of a water bath for 24 h; the mass gain divided by the immersed face area gives the short-term water absorption Wp in kg/m². Because the specimen is only partly immersed, the result is governed by capillary suction and surface wetting rather than by saturation of the whole volume, so it responds strongly to hydrophobic treatment of mineral wool and to the skin or surface finish of foams. The standard offers two methods, A and B, which differ in how the specimen is handled and drained; product standards specify which one applies.

    Specimens, conditioning and procedure

    Square specimens of 200 mm side length are cut at the product thickness, conditioned and weighed. Each is placed in a tank on supports so that the lower face lies 10 mm below the water surface, with the water level kept constant and the specimen prevented from floating, and left for 24 h. On removal the specimen is drained for the short period defined in the standard, in the orientation it prescribes, and weighed again. The client confirms which face is to be immersed when the product has a facing or a different finish on each side, which method, A or B, is required by the product standard, and whether cut edges are to be sealed as the standard allows for certain products.

    What the report states

    The report lists for each specimen the mass before and after immersion, the immersed area and the short-term water absorption Wp in kg/m², with the mean of the set and the method used. Mineral wool manufacturers compare the mean with the WS level, which requires a value not exceeding 1.0 kg/m²; other product standards define their own levels or thresholds. The orientation of the immersed face is stated.

    Where the result is required

    The WS characteristic in EN 13162 for mineral wool rests on this method, and it is used in the same form for wood fibre, cellular glass and other factory-made insulation standards that declare short-term water absorption. ETICS kits under EAD 040083 and ventilated facade insulation specifications call for it to show that boards shed rain during construction. For prolonged exposure the long-term tests of EN 12087 apply instead.

    What we assess

    • short-term water absorption

    Products covered

    • thermal insulation products (MW, EPS, XPS, PIR, PUR, wood fibre)
    • building materials

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Both immerse the lower face to the same depth for the same time; they differ in the handling and draining of the specimen before weighing, which affects how much surface water is counted. The product standard names the method to use, so the laboratory applies the one the declaration refers to and states it in the report. Results from the two methods are not pooled.

    It means the product resists wetting during a short exposure, which is what the test simulates. It says nothing about moisture uptake by diffusion over years, freeze-thaw or standing water on an inverted roof; those cases are covered by EN 12087, EN 12088 and EN 12091. Designers combine the results according to the application.

    The face that will be exposed to water in the intended use, agreed with the client before testing. For boards with a facing on one side both orientations are often tested, because the unfaced side represents handling and storage while the faced side represents the installed condition. The report identifies the immersed face for each specimen.

    Related standards