Harmonised or product standard

    EN 13163 - Thermal insulation products for buildings - factory made expanded polystyrene (EPS) products

    Certification · NAC-026-PPS

    In short

    EN 13163 - Thermal insulation products for buildings - factory made expanded polystyrene (EPS) products. For expanded polystyrene (EPS) products, Amstelfy covers thermal resistance / conductivity, dimensions and dimensional stability, compressive behaviour and tensile strength perpendicular to faces and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13163 specifies factory-made expanded polystyrene products, moulded or cut from blocks, with or without facings, used as thermal insulation in buildings. Beyond the characteristics common to all insulation standards it reflects EPS technology: bending strength BS under EN 12089 is required for every product because it indicates bead fusion, compressive stress CS(10) under EN 826 defines the commercial grades, deformation under load and temperature DLT under EN 1605 and compressive creep CC under EN 1606 cover loaded applications, tensile strength TR under EN 1607 covers ETICS, long-term water absorption WL(T) by total immersion and WD(V) by diffusion cover ground contact, and freeze-thaw resistance follows EN 12091. Thermal conductivity is declared from measurements at 10 °C under the 90/90 statistic, with the thickness effect of light grades handled by EN 12939. The standard also gives tabulated water vapour resistance factors by density so that MU can be declared without testing.

    Type testing and factory production control

    Initial type testing starts with the characteristics required for all products: thermal resistance, length, width, thickness, squareness and flatness, dimensional stability under normal laboratory conditions and bending strength, plus reaction to fire. Application-dependent tests follow on the same product groups: compressive stress at 10 % deformation, dimensional stability at 70 °C with and without humidity, deformation under specified load and temperature for DLT, creep, tensile strength perpendicular, water absorption and vapour transmission. Specimens are cut from blocks or taken as moulded boards according to the specimen sizes the standard allocates to each method. Factory production control concentrates on density, dimensions, conductivity and bending or compressive strength at the frequencies tabulated in the standard; reaction to fire class E, the usual class with flame retardant, falls under AVCP system 3 and the other characteristics under system 3 as well.

    What the report states

    Reports present each measured characteristic against the declared class or level, for example CS(10)100, BS150, DS(N)2, DS(70,-)1, TR100, WL(T)3, and the λD and RD values by thickness. The manufacturer assembles them into the Declaration of Performance and the designation code on the label. Under the ISO/IEC 17065 scheme a certificate confirms the sampled products stay within the declared levels between surveillance visits.

    Where the result is required

    EPS under EN 13163 is the main insulation in bonded ETICS under EAD 040083, in floor and flat roof build-ups, perimeter and under-slab insulation, cavity walls and precast sandwich elements. National application standards translate the EN 13163 codes into grades for specific uses, so a correct set of declared levels opens those markets. The same data support conductivity verification in certification schemes for ETICS kits and in EPD background data for polystyrene products.

    What we assess

    • thermal resistance / conductivity
    • dimensions and dimensional stability
    • compressive behaviour
    • tensile strength perpendicular to faces
    • water absorption
    • water vapour transmission

    Products covered

    • expanded polystyrene (EPS) products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    It is on the ISO/IEC 17065 certification scope NAC-026-PPS; the related test methods are on the ISO/IEC 17025 testing scope.

    Bending strength under EN 12089 is a sensitive indicator of how well the beads have fused during moulding. Poorly fused blocks reach their nominal density and even a passable compressive stress but break along bead boundaries, so the standard makes BS a mandatory characteristic and a key factory production control parameter, independent of the application.

    Trade names such as EPS 100 derive from national application standards and usually correspond to a compressive stress at 10 % deformation of at least 100 kPa, which in EN 13163 terms is CS(10)100. The Declaration of Performance must carry the EN 13163 code and level; the trade grade may appear in commercial documents only, and the mapping differs between countries.

    Yes, EN 13163 provides tabulated μ ranges by density that a manufacturer may declare without measurement. A measured value under EN 12086 is needed when the product has a facing, when a more precise figure is wanted for condensation calculations, or when a customer specification asks for test evidence rather than a tabulated figure.

    Related standards

    All Thermal insulation products & hygrothermal test methods testing