Test method

    ASTM C518 – Thermal conductivity testing

    Standard test method for steady-state thermal transmission properties by means of the heat flow meter apparatus

    Testing · NAC-037-TL

    In short

    ASTM C518 - Standard test method for steady-state thermal transmission properties by means of the heat flow meter apparatus. Amstelfy's laboratory determines thermal conductivity (heat flow meter) of thermal insulation products (MW, EPS, XPS, PIR, PUR, wood fibre) and building materials according to ASTM C518 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What ASTM C518 determines

    ASTM C518 is the North American heat flow meter method for steady-state thermal transmission properties. Like ISO 8301 it uses a specimen sandwiched between two isothermal plates and a calibrated heat flux transducer, but it stands alone as a complete test method with its own requirements for apparatus verification, calibration with transfer standards and reporting. It determines apparent thermal conductivity, thermal resistance (R-value) and thermal conductance, the word apparent acknowledging that radiation and convection inside a porous material are folded into one coefficient. Because the transducer is calibrated against reference materials, the result is only as good as the match between calibration range and specimen in thickness, resistance and temperature. The method is cited by most ASTM material specifications for insulation.

    Specimens, conditioning and procedure

    The specimen is a flat slab, cut or moulded to the plate size, with its thickness measured in the apparatus under the plate load for compressible products. Conditioning follows the governing material specification or the client's instruction. The apparatus is verified against a reference specimen before the series, then the plates are set to the mean temperature and temperature difference requested; North American specifications usually call for a 75 °F (24 °C) mean, whereas European declarations use 10 °C. Readings are taken once the heat flux signal is steady within the drift criterion. Clients choose the mean temperature or a series of temperatures, the configuration (single specimen with one or two transducers, or two specimens) and the units for reporting.

    What the report states

    Reported are apparent thermal conductivity in W/(m·K) and, where requested, BTU·in/(h·ft²·°F), thermal resistance in m²·K/W or the imperial R-value, thermal conductance, mean temperature, temperature difference, thickness, density and conditioning history. Results are given per specimen with the mean of replicates. Manufacturers compare them with the limits in the material specification or use them to establish R-value labelling.

    Where the result is required

    ASTM C518 is the thermal test behind material specifications such as ASTM C578 for rigid cellular polystyrene, ASTM C612 for mineral fibre board and ASTM C1289 for polyisocyanurate board, and behind R-value claims in North American and Middle Eastern projects that specify ASTM. European manufacturers exporting to those markets need C518 data alongside their EN results. The same apparatus run under ISO 8301 or EN 12667 serves the CE marking file.

    What we assess

    • thermal conductivity (heat flow meter)

    Products covered

    • thermal insulation products (MW, EPS, XPS, PIR, PUR, wood fibre)
    • building materials

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The apparatus and physics are the same, so a measurement at identical mean temperature, conditioning and thickness gives the same conductivity within uncertainty. Declared values are not interchangeable, because EN product standards use a 10 °C mean and a 90/90 statistical limit, while ASTM specifications usually quote 24 °C and compare individual results with a limit.

    For porous insulation the heat crossing the specimen combines conduction through solid and gas with radiation and, in open products, some convection. The heat flow meter cannot separate them and reports a single effective coefficient for the tested thickness and temperature, which is why ASTM calls it apparent thermal conductivity.

    At minimum the temperature the target specification names, commonly 75 °F (24 °C). Many buyers also ask for values at lower and higher means to show the temperature dependence; three to five points spanning the service range give a usable curve, and the 10 °C point links the data set to the European declaration.