Harmonised or product standard

    EN 13164 - Thermal insulation products for buildings - factory made extruded polystyrene foam (XPS) products

    Certification · NAC-026-PPS

    In short

    EN 13164 - Thermal insulation products for buildings - factory made extruded polystyrene foam (XPS) products. For extruded polystyrene foam (XPS) products, Amstelfy covers thermal resistance / conductivity, dimensions and dimensional stability, compressive behaviour and tensile strength perpendicular to faces and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13164 specifies extruded polystyrene foam boards, with extrusion skin or planed faces and with butt, shiplap or tongue-and-groove edges, used as thermal insulation in buildings. Two features set it apart from the EPS standard. First, XPS is blown with gases that diffuse out slowly and are replaced by air, so the declared thermal conductivity has to represent the aged product; its annex on aged values prescribes how initial measurements under EN 12667 are converted, by fixed increments or accelerated ageing, into the λD to be declared. Second, the standard is built around wet and loaded applications: compressive stress or strength CS(10\Y) under EN 826, compressive creep CC under EN 1606, deformation under load and temperature DLT under EN 1605, dimensional stability DS(70,90) under EN 1604, long-term water absorption WL(T) and WD(V), freeze-thaw resistance under EN 12091 and water vapour transmission MU. Thickness tolerances are expressed in T classes.

    Type testing and factory production control

    Type testing includes conductivity on fresh boards with the ageing evaluation of the annex, dimensions and thickness class, dimensional stability at 70 °C and 90 % relative humidity, and compressive stress or strength on specimens that keep the production surface. Application tests follow: creep under sustained compressive load, deformation under load at elevated temperature, tensile strength perpendicular to faces, total-immersion water absorption under EN 12087 method 2A, diffusion water absorption under EN 12088, freeze-thaw cycling after wetting under EN 12091 with the retained compressive strength and absorption measured, and vapour transmission under EN 12086. Factory production control follows the frequencies tabulated in the standard, with density, thickness, compressive strength and conductivity as the routine controls; AVCP is system 3 for reaction to fire class E and for the other characteristics.

    What the report states

    Reports state each characteristic against the declared class, for instance CS(10\Y)300, CC(2/1.5/50)130, DS(70,90)5, WL(T)0.7, and the aged λD with the derived RD per thickness. The manufacturer uses them for the Declaration of Performance and the designation code. Under the ISO/IEC 17065 scheme a certificate attests continued conformity on the basis of sampled retests between audits.

    Where the result is required

    XPS under EN 13164 is specified where insulation meets water, load or both: inverted roofs, perimeter and basement walls, floors under slabs and industrial pavements, cold stores, and behind external renders on plinths. National rules for inverted roofs and ground-contact insulation refer to the WL(T), WD(V), freeze-thaw and CC classes of this standard, and civil engineering specifications for frost protection under roads and railways refer to its compressive and water absorption classes.

    What we assess

    • thermal resistance / conductivity
    • dimensions and dimensional stability
    • compressive behaviour
    • tensile strength perpendicular to faces
    • water absorption
    • water vapour transmission

    Products covered

    • extruded polystyrene foam (XPS) products

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    It is on the ISO/IEC 17065 certification scope NAC-026-PPS; the related test methods are on the ISO/IEC 17025 testing scope.

    The cell gas of many XPS boards is partly a blowing agent with lower conductivity than air; over years it diffuses out and air diffuses in, raising the conductivity. EN 13164 therefore requires the declared λD to represent the aged product, derived from fresh measurements by the procedures in its annex, which depend on the blowing agent, the thickness and whether diffusion-tight facings are present.

    It signals that the declared value may be either the compressive stress at 10 % deformation or the compressive strength at yield, whichever EN 826 produces first for the product. Many XPS grades yield before 10 % deformation, so the strength at the maximum force is the governing number; the code tells the user which quantity to expect.

    The classes for long-term water absorption by total immersion WL(T), water absorption by diffusion WD(V) and freeze-thaw resistance, together with compressive strength and creep under the ballast load. National application rules set the required classes; the laboratory runs the four test series on the same product and reports the retained compressive strength after freeze-thaw.

    Related standards

    All Thermal insulation products & hygrothermal test methods testing