Test method

    EN 12085 - Thermal insulating products - linear dimensions of test specimens / dimensional stability under specified conditions

    Testing · NAC-037-TL

    In short

    EN 12085 - Thermal insulating products - linear dimensions of test specimens / dimensional stability under specified conditions. Amstelfy's laboratory determines dimensional stability under temperature and humidity of thermal insulation products (MW, EPS, XPS, PIR, PUR, wood fibre) and building materials according to EN 12085 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 12085 determines

    EN 12085 specifies how the linear dimensions of test specimens cut from thermal insulating products are measured: length, width and thickness, with the measuring devices, their resolution, the positions of measurement and the way results are averaged. It exists because nearly every insulation test method expresses its result per unit area or volume or as a relative change of dimension, and those results are only comparable if the specimen dimensions are taken the same way everywhere. The method concerns specimens, not whole boards; dimensions of delivered products are measured under EN 822 and EN 823. It is also the measuring procedure behind dimensional stability: EN 1603 (constant normal laboratory conditions) and EN 1604 (specified temperature and humidity) define the exposure, and EN 12085 measurements before and after the exposure give the change in length, width and thickness.

    Specimens, conditioning and procedure

    Specimens are conditioned and placed on a flat reference surface. Length and width are measured with callipers or a rule of the required resolution at the positions the standard defines and averaged; thickness is taken with a gauge whose foot applies only a light, defined contact pressure so that compressible products are not indented, at several points across the face. For dimensional stability the same specimens are measured, marked, exposed under EN 1604 at the chosen condition, commonly 48 h at 70 °C and 90 % relative humidity or at 70 °C in dry air, allowed to return to laboratory climate and measured again at the same points. Clients state which dimensional-stability condition and which product thickness they intend to declare; faced products are measured with the facing in place.

    What the report states

    The report gives the measured length, width and thickness of each specimen with the device used. When the measurement frames a dimensional-stability exposure it also gives the relative change of each dimension in per cent, from which the manufacturer declares DS(N)i, DS(70,-)i or DS(70,90)i levels, with i the maximum permitted change. The same dimensions enter the area and volume used in the other test results.

    Where the result is required

    EN 12085 is referenced by the insulation test methods for compression, tensile strength, water absorption and vapour transmission whenever specimen dimensions are needed, and through EN 1603 and EN 1604 it underpins the DS characteristics in EN 13162, EN 13163 and EN 13164. Dimensional stability under heat and humidity is decisive for EPS and XPS in ETICS and flat roofs, where shrinkage opens joints, and for the ETICS assessments under EAD 040083.

    What we assess

    • dimensional stability under temperature and humidity

    Products covered

    • thermal insulation products (MW, EPS, XPS, PIR, PUR, wood fibre)
    • building materials

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Not on its own. EN 12085 is the measuring method; the exposure that produces a dimensional change is defined in EN 1603 for storage at constant laboratory conditions and in EN 1604 for specified temperature and humidity. A dimensional-stability result therefore quotes both documents: EN 1604 for the conditions and EN 12085 for how the dimensions were taken.

    Soft products compress under the foot of an ordinary gauge, and a thickness that is too low raises every result expressed per unit volume and shifts the apparent dimensional change. The standard therefore fixes a light contact pressure and the foot area so that mineral wool and foams are measured consistently between laboratories.

    EN 13163 requires DS(N) under constant normal laboratory conditions for every product and adds DS(70,-) for applications with heat. Products for flat roofs and ETICS are usually declared at the 70 °C condition, because shrinkage at service temperature opens board joints. The laboratory runs the condition the manufacturer intends to declare and reports the change in each direction.

    Related standards