US qualification standard

    ASTM C94 - Standard specification for ready-mixed concrete

    Certification · NAC-026-PPS

    In short

    ASTM C94 - Standard specification for ready-mixed concrete. For ready-mixed concrete, Amstelfy covers certification against the specification as an ISO/IEC 17065-accredited product certification body (NAC-026-PPS).

    What ASTM C94 determines

    ASTM C94/C94M is the purchase specification for concrete batched at a plant and delivered in a plastic state. It defines what the purchaser must state when ordering, using Option A, where the producer selects proportions to meet a specified strength, Option B, where the purchaser prescribes proportions, or Option C, where strength and a minimum cement content are both specified. It sets requirements for materials, batching accuracy, mixer performance and uniformity, delivery time and drum revolutions, the information on the delivery ticket, and the sampling and testing of the delivered concrete. Acceptance is based on slump, air content, temperature and compressive strength, with statistical strength criteria consistent with ACI 318. It is a specification, so conformity means the producer's operations and the delivered loads meet these clauses.

    Specimens, conditioning and procedure

    A certification assessment against ASTM C94 reviews the plant's scales and batching records against the tolerances for cementitious materials, aggregates, water and admixtures, the mixer uniformity test in which two samples from one batch are compared on six properties, the control of delivery time and drum revolutions, and the content of delivery tickets. Delivered concrete is sampled under ASTM C172 and tested for slump under ASTM C143, air content, temperature and strength by ASTM C39 cylinders made under ASTM C31. Strength records are evaluated as the average of three consecutive tests and the individual test shortfall against the specified strength. The testing of slump and cylinders sits on the laboratory's testing scope.

    What the report states

    The assessment reports plant compliance clause by clause and the test results of delivered loads: slump against the ordered value and its tolerance, air content within ±1.5 percentage points of the specified value, and strength tests meeting both the running average and the individual-test criteria. A voluntary certificate confirms the producer's conformity with the specification for the plant assessed.

    Where the result is required

    Ready-mixed concrete supply to projects designed and specified under ACI 318, IBC and US federal or corporate specifications executed in Europe, the Middle East and Africa, prequalification of plants supplying US-standard projects such as embassies, military and industrial facilities, and producer quality programmes modelled on US practice. It is also the frame within which ASTM C1116 fibre-reinforced concrete is ordered.

    What we assess

    • certification against the specification

    Products covered

    • ready-mixed concrete

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    It is on the ISO/IEC 17065 certification scope NAC-026-PPS; the related test methods are on the ISO/IEC 17025 testing scope.

    A strength test is the average of cylinders from one sample, two 150 mm or three 100 mm cylinders at the specified age. The average of any three consecutive tests must equal or exceed the specified strength, and no individual test may fall below it by more than 3.5 MPa when the specified strength is 35 MPa or less.

    Discharge must be completed within one and a half hours after the water is first added, or before the drum has turned 300 revolutions, whichever comes first, unless the purchaser allows otherwise. Hot weather, retarders and water additions on site are handled by specific clauses that must be recorded on the ticket.

    Two samples are taken from the same batch after about 15 % and 85 % of the load has discharged and compared on properties including slump, air content, coarse aggregate content, mortar unit weight, concrete density and compressive strength. Differences within the specified limits show the mixer blends the batch uniformly.

    Related standards

    All Concrete, fibres, mortars & concrete repair products testing