Test method
EN ISO 10319 - Geosynthetics - wide-width tensile test
In short
EN ISO 10319 - Geosynthetics - wide-width tensile test. Amstelfy's laboratory determines wide-width tensile strength and elongation of geotextiles, geogrids and geocomposites according to EN ISO 10319 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.
What EN ISO 10319 determines
EN ISO 10319 is the reference tensile test for geosynthetics. A strip 200 mm wide, with a nominal gauge length of 100 mm between the clamps, is extended at a constant rate of strain of 20 % per minute until it breaks, and force and elongation are recorded throughout. The width is deliberately large: a narrow strip of a woven or a needle-punched nonwoven necks in and sheds load through its edges, whereas a 200 mm specimen behaves more like the product in the ground, where soil restrains it laterally. The method gives the maximum tensile force per unit width, the strain at that force and, on request, the force at specified strains that reinforcement design uses. Results are given for both directions, since most products are anisotropic. Geogrids are tested as whole ribs, normalised per metre width.
Specimens, conditioning and procedure
At least five specimens per direction are cut to EN ISO 9862 and conditioned where required; wet testing after soaking is an option for moisture-sensitive products. Each specimen is mounted in clamps wide enough to grip the full 200 mm without slippage or clamp breaks; roller, wedge or capstan jaws are chosen to suit the product. Strain is measured over gauge marks on the specimen with a contact or optical extensometer rather than from crosshead travel. The crosshead moves at 20 % strain per minute of the gauge length until rupture, the force-strain curve is recorded and the failure location is noted. Geogrid specimens contain a defined number of ribs, and the rib count per metre converts force to kN/m.
What the report states
The report gives, per direction, the tensile strength in kN/m (maximum force per unit width), the elongation at maximum force in percent and, where requested, the force at 2 % and 5 % strain or the secant stiffness, each with individual values, mean and coefficient of variation. Failure modes and any clamp breaks are stated. The manufacturer declares the mean with a tolerance at the 95 % confidence level in the Declaration of Performance.
Where the result is required
Tensile strength and elongation to EN ISO 10319 are required characteristics in every harmonised geotextile standard, EN 13249 to EN 13257 and EN 13265, whatever the function, and the method is the basis for the retained-strength ratios in the durability screening tests EN 12224, EN 12225, EN 12447, EN ISO 13438 and EN 14030. Seam strength under EN ISO 10321 is compared with it. For geogrid reinforcement the short-term strength from this test is the starting point from which creep, installation damage and durability reduction factors give the design strength.
- EN ISO 10321 – seam strength by the same wide-width method
- EN 12224 – retained strength after weathering
- EN ISO 13438 – retained strength after oxidation
- EN 13252 – required characteristic for drainage products
- EN 13253 – required characteristic for erosion control products
- EN ISO 9862 – specimen cutting and conditioning
What we assess
- wide-width tensile strength and elongation
Products covered
- geotextiles
- geogrids
- geocomposites
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EN ISO 9862 - Geosynthetics - sampling and preparation of test specimens
- EN ISO 9863-1 - Geosynthetics - thickness at specified pressures - single layers
- EN ISO 9864 - Geosynthetics - mass per unit area of geotextiles and geotextile-related products
- EN ISO 10318 - Geosynthetics - terms and definitions
- EN ISO 10321 - Geosynthetics - tensile test for joints/seams by wide-width strip method
- EN ISO 11058 - Geotextiles - water permeability characteristics normal to the plane, without load
- EN ISO 12236 - Geosynthetics - static puncture test (CBR test)
- EN ISO 12956 - Geotextiles - characteristic opening size