Test method

    EN ISO 11058 - Geotextiles - water permeability characteristics normal to the plane, without load

    Testing · NAC-037-TL

    In short

    EN ISO 11058 - Geotextiles - water permeability characteristics normal to the plane, without load. Amstelfy's laboratory determines permeability normal to plane of geotextiles, geogrids and geocomposites according to EN ISO 11058 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN ISO 11058 determines

    EN ISO 11058 measures how readily water passes through a geotextile perpendicular to its plane when it is not under load. A circular specimen is held in a permeameter and de-aired water flows through it under a small hydraulic head; from the flow rate and the specimen area the flow velocity is obtained, and the result is expressed as the velocity index VIH50, the velocity at a head loss of 50 mm across the specimen, corrected to a water temperature of 20 °C. Two procedures are allowed: the constant-head method, where velocity is measured at several heads and the value at 50 mm is read from the fitted curve, and the falling-head method, where the drop of the head between two levels is timed. The index describes the clean product; clogging depends on the soil and is not covered.

    Specimens, conditioning and procedure

    Specimens are cut to fit the permeameter from across the sample and are soaked in de-aired water, with a wetting agent where specified, so that trapped air in the fibre structure does not restrict flow. Each specimen is clamped in the cell, the system is flushed free of air bubbles and the chosen method is run: for constant head, flow is measured at a series of head losses within the range given in the standard; for falling head, the drop between two marked levels is timed repeatedly. Water temperature is recorded and the velocities are corrected to 20 °C using the viscosity ratio. The permeability coefficient follows by multiplying the velocity index by the thickness from EN ISO 9863-1.

    What the report states

    The report states the velocity index VIH50 in mm/s (or m/s) for each specimen and the mean with coefficient of variation, the method used, the water temperature and whether a wetting agent was applied. Optionally the permittivity and the permeability coefficient in m/s are given. The manufacturer declares the velocity index with its tolerance as the water permeability characteristic in the Declaration of Performance.

    Where the result is required

    Water permeability normal to the plane is a required characteristic for the filtration function in all the geotextile product standards, including EN 13252 for drainage systems, EN 13253 for erosion control and EN 13254 for reservoirs and dams, and it is the companion to characteristic opening size in filter design. It is quoted for nonwoven filter wraps around drains, filters under riprap and armour stone, separation layers in roads and the filter jackets of geocomposite drains.

    What we assess

    • permeability normal to plane

    Products covered

    • geotextiles
    • geogrids
    • geocomposites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    The velocity index is the measured flow velocity at a 50 mm head and is the quantity declared in Europe. Permittivity divides velocity by head and is the usual US quantity. The permeability coefficient multiplies the velocity index by the geotextile thickness and allows comparison with soils, but it depends on the thickness convention used.

    Air held in the pore structure of a nonwoven or trapped under a woven blocks part of the flow area and gives a low, unstable reading. Soaking with a wetting agent and using water with the dissolved air removed lets the flow stabilise, so the measured value reflects the open structure of the product and not the test setup.

    No. It measures the clean product without load. Clogging and long-term filter behaviour depend on the soil grading, the hydraulic regime and the opening size, and are assessed with soil-geotextile performance tests such as the gradient ratio or long-term filtration tests, outside this index method.

    Related standards

    All Geotextiles & geosynthetics testing