Test method

    EN ISO 9863-1 - Geosynthetics - thickness at specified pressures - single layers

    Testing · NAC-037-TL

    In short

    EN ISO 9863-1 - Geosynthetics - thickness at specified pressures - single layers. Amstelfy's laboratory determines thickness of geotextiles, geogrids and geocomposites according to EN ISO 9863-1 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN ISO 9863-1 determines

    EN ISO 9863-1 defines thickness as the distance between a flat reference plate and a parallel circular presser foot that applies a defined pressure to a single-layer specimen for a set time. The pressure matters because nonwoven geotextiles are compressible: a product may lose a large part of its thickness between the 2 kPa reference pressure and the 200 kPa that represents soil cover under traffic. The standard therefore uses 2 kPa for the nominal thickness and 20 kPa and 200 kPa as optional higher pressures, giving a simple compressibility profile. Thickness is an identification and FPC property rather than a declared performance characteristic, but it enters other results: the permeability coefficient from EN ISO 11058 is the velocity index multiplied by thickness, and in-plane flow depends directly on the compressed thickness. Multilayer products are covered by EN ISO 9863-2.

    Specimens, conditioning and procedure

    Specimens larger than the presser foot are cut according to EN ISO 9862 and conditioned where needed. Each specimen is placed on the reference plate, the presser foot of 25 cm² area is lowered without impact so that the 2 kPa pressure acts, and the gauge reading is taken after the dwell time in the standard. Where the higher pressures are required, the load is increased on the same specimen to 20 kPa and then 200 kPa with the same dwell and reading sequence. The apparatus is checked for parallelism and the gauge resolution meets the standard. A set of ten specimens is normally tested, with the client choosing whether the 20 kPa and 200 kPa steps are included.

    What the report states

    The report gives thickness in millimetres for each specimen and the mean at each pressure, with the coefficient of variation, and states the presser foot pressure sequence used. From the 2 kPa value the nominal thickness is declared; the 20 kPa and 200 kPa values show how much the product compresses under load. Manufacturers use the figures for product data sheets, FPC control charts and as input for permeability calculations.

    Where the result is required

    The product standards for geotextiles cite EN ISO 9863-1 for identification and factory production control, and thickness is one of the routine FPC checks alongside mass per unit area. It is needed to convert the velocity index of EN ISO 11058 into a permeability coefficient, to interpret EN ISO 12958 in-plane flow at different normal stresses and to compare protection geotextiles for geomembranes. Drainage geocomposites and other multilayer products require the multilayer method EN ISO 9863-2.

    What we assess

    • thickness

    Products covered

    • geotextiles
    • geogrids
    • geocomposites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    A calliper applies an uncontrolled pressure, and for a needle-punched nonwoven a small change in contact pressure changes the reading markedly. Fixing the presser foot area and pressure makes the value reproducible between laboratories and between production checks, which is the purpose of an index property.

    They are optional and are chosen when the product will work under soil or traffic load and compressibility matters, for example protection geotextiles on geomembranes, drainage layers and cushion layers under paving. For identification and FPC purposes the 2 kPa nominal thickness is usually sufficient.

    Single-layer geogrids can be measured at rib or junction positions provided the presser foot rests on material, and the position is reported. Geocomposites and other multilayer products fall under EN ISO 9863-2, which addresses the individual layers and the interaction between them.

    Related standards

    All Geotextiles & geosynthetics testing