Test method

    EN ISO 12956 - Geotextiles - characteristic opening size

    Testing · NAC-037-TL

    In short

    EN ISO 12956 - Geotextiles - characteristic opening size. Amstelfy's laboratory determines characteristic opening size O90 of geotextiles, geogrids and geocomposites according to EN ISO 12956 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN ISO 12956 determines

    EN ISO 12956 determines the characteristic opening size O90 of a geotextile by using the product itself as a sieve. A graded granular material, sand or glass beads, is wet-sieved through a clamped specimen under water spray and vibration; the fraction that passes is collected, dried and sieved on standard test sieves, and its grain size distribution is plotted. O90 is the d90 of that passed fraction, the size that 90 % of the openings are smaller than, expressed in micrometres. Filter rules compare O90 with the d85 or d90 of the soil to be retained and with the opening needed to stay permeable. It is a hydrodynamic measurement of effective openings in a wet, vibrated state, which for a nonwoven differs from the geometric pore size under a microscope or from dry sieving.

    Specimens, conditioning and procedure

    Specimens are cut to fit the sieving frame, soaked and mounted flat and taut over the support. A measured mass of granular material whose grading brackets the expected opening size is spread on the specimen and the assembly is sieved under a steady water spray for the period fixed in the standard, with the vibration set by the apparatus requirements. The material that has passed through is collected, dried and sieved through a stack of test sieves, and the grading curve of the passed fraction is drawn. The test is repeated on a set of specimens, and the granular material is chosen so that O90 falls within its graded range; otherwise the test is repeated with a different fraction.

    What the report states

    The report gives O90 in micrometres for each specimen and the mean with the coefficient of variation, the granular material used and its grading, and the sieving conditions. The manufacturer declares the mean O90 with a two-sided tolerance in the Declaration of Performance. Designers use it against the soil grading in retention and permeability criteria for filters.

    Where the result is required

    Characteristic opening size is a required characteristic for the filtration function in all the harmonised geotextile standards, including EN 13252 for drainage systems, EN 13253 for erosion control works and EN 13254 for reservoirs and dams, and it is the quantity used in national filter design rules for geotextiles under riprap, around drains and beneath revetments. It is paired with water permeability from EN ISO 11058 to show that a filter retains soil and still passes water.

    What we assess

    • characteristic opening size O90

    Products covered

    • geotextiles
    • geogrids
    • geocomposites

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    No. AOS (O95) under the US dry-sieving method uses dry glass beads without water, and the two methods give different values for the same nonwoven because moisture, vibration and bead agglomeration behave differently. European product standards and filter rules call for O90 to EN ISO 12956; the values should not be converted from one to the other.

    Retention rules require O90 to be smaller than a multiple of a characteristic soil grain size, such as d85 or d90, so that the soil skeleton is held. Permeability rules require it to be larger than a lower bound so that fines can pass and the filter does not blind. The declared O90 with its tolerance has to satisfy both.

    If the granular material is too coarse nothing passes and O90 cannot be read; if it is too fine everything passes and the result is just the material's own grading. The standard requires a fraction that brackets the opening size, and the laboratory repeats the test with another fraction when the first result falls outside its range.

    Related standards

    All Geotextiles & geosynthetics testing