Test method

    EN 1925 - Natural stone test methods - water absorption coefficient by capillarity

    Testing · NAC-037-TL

    In short

    EN 1925 - Natural stone test methods - water absorption coefficient by capillarity. Amstelfy's laboratory determines capillary water absorption of natural stone according to EN 1925 under its ISO/IEC 17025 accreditation (NAC-037-TL). The method is typically part of initial type testing, ETA test programmes or factory production control verification; results are reported in English for manufacturers across Europe.

    What EN 1925 determines

    EN 1925 determines the water absorption coefficient by capillarity of natural stone: how fast water is drawn into the stone through one face by capillary suction, without any head. Dried specimens stand on supports in a tray of water a few millimetres deep and are weighed at increasing intervals; the mass gain per unit area of the wetted face is plotted against the square root of time and the slope of the initial linear part is the coefficient C1, in g/(m²·√s). Some stones show a second, flatter linear section as the finer pores fill, reported as C2. The coefficient governs rising damp in plinths and copings, the wetting of paving, salt penetration and drying after rain, and it is sensitive to bedding, so anisotropic stones are tested in more than one direction. It complements the total absorption from EN 13755.

    Specimens, conditioning and procedure

    A set of specimens, normally six, is prepared as cubes or cylinders with plane sawn faces; anisotropic stones get two sets, with water entering perpendicular and parallel to the planes. The specimens are dried at 70 °C to constant mass, cooled in a desiccator and weighed, and the area of the test face is measured. Each specimen is placed on supports in a tray so that the test face stands in water 3 mm deep, the level being kept constant, and is removed, blotted and weighed at the intervals set in the standard, frequent at first and longer later, until the uptake curve has become linear in its final section or the specimen is saturated. Temperature is recorded.

    What the report states

    The report gives for each specimen the coefficient C1 in g/(m²·√s), and C2 where a second linear section exists, the time range over which each slope was taken, the orientation relative to bedding, and the mean values with their scatter; the mass-gain curves are included. Manufacturers declare the capillarity coefficient where their product standard lists it, and conservation specifiers use it to match replacement stone and to judge compatibility with mortars and treatments.

    Where the result is required

    The capillarity coefficient is a declared characteristic in natural stone product standards where water uptake from the ground or from surfaces matters, including EN 1469 for external cladding, EN 12057 for modular tiles and EN 12058 for floor slabs used externally, and it is used with EN 771-6 for masonry units in plinths and exposed walls. It is also central to the assessment of stone consolidants and water repellents, to rising damp investigations and to the durability classification of sandstones and limestones.

    What we assess

    • capillary water absorption

    Products covered

    • natural stone

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    This test method is used inside initial type testing, ETA assessment programmes and factory production control verification. Amstelfy reports it as an accredited test under NAC-037-TL, either stand-alone or as part of a complete test programme.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Many stones have a bimodal pore structure: coarse pores fill quickly and give the steep initial slope C1, then fine pores continue to fill slowly and give a second, flatter slope C2. The standard provides for reporting both with the time ranges over which they were measured, so the user can see which regime applies to the exposure in question.

    Capillary rise is faster parallel to sedimentary bedding or foliation than across it, sometimes by a large factor. The standard requires anisotropic stones to be tested with water entering perpendicular and parallel to the planes, and the two coefficients are reported separately, so the specifier can orient the stone correctly in copings, plinths and steps.

    Six specimens per orientation, cut as cubes or cylinders of the size the standard allows, so a single slab offcut or small block is usually sufficient. Specimens must be free of cracks and surface treatments, and the client should state the bedding direction if it is not visible, because the laboratory marks it before cutting.

    Related standards

    All Natural stone & masonry ancillary components testing