Harmonised or product standard

    EN 845-5 - Ancillary components for masonry - lintels

    Testing · NAC-037-TL

    In short

    EN 845-5 - Ancillary components for masonry - lintels. For prefabricated lintels, Amstelfy covers load-bearing capacity and deflection in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    The lintel part of the EN 845 series, published by CEN as EN 845-2, covers prefabricated lintels that bridge openings in masonry: steel lintels, reinforced and prestressed concrete lintels, autoclaved aerated concrete, manufactured and natural stone lintels, clay units with concrete infill, and composite lintels that rely on the masonry built above them. The manufacturer declares the load-bearing capacity and the deflection behaviour for each span, bearing length and, for composite types, the minimum height of masonry above. Capacity may come from testing to EN 846-9, from calculation to the relevant Eurocode, or from a combination. The standard also fixes dimensional tolerances and bow (EN 846-11), the material and corrosion-protection reference for steel parts, cover to reinforcement and, for composite lintels, the shear bond with the masonry above (EN 846-14). Conformity is shown by type testing and factory production control.

    Type testing and factory production control

    For a flexural test the lintel is placed on bearings at the declared end-bearing length and loaded symmetrically, normally through a spreader beam giving two point loads or an equivalent distributed load, while mid-span deflection is recorded against load. Composite lintels are tested with the specified courses of masonry built on top and cured before loading. Load is applied in increments to failure, and the load at the deflection limit and the ultimate load are identified. A test series covers the span range and cross-sections to be declared; intermediate spans may be interpolated under the rules of the standard. Dimensional checks measure length, section, straightness and bow. Factory production control covers materials, welding or reinforcement placement, concrete strength and dimensions.

    What the report states

    The report lists ultimate loads and load-deflection curves for each specimen, the failure mode (yielding, cracking, shear, bearing crushing or loss of composite action) and the derived declared load-bearing capacity in kN or kN/m for the tested span, together with the deflection at the declared load. Dimensions and bow are tabulated against the tolerance class. These become the values in the manufacturer's load tables and Declaration of Performance.

    Where the result is required

    The specification is cited for CE marking of lintels placed on the EU market and by designers checking lintel schedules against Eurocode 6 and national masonry rules. Products include galvanised and stainless steel box, angle and cavity lintels, precast prestressed concrete lintels, aerated concrete lintels, cast stone and natural stone heads. Where an existing design is changed, for example a new steel grade or coating, a reduced test series under the same standard confirms the declared capacity.

    What we assess

    • load-bearing capacity
    • deflection

    Products covered

    • prefabricated lintels

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    A composite lintel carries load only together with the masonry built above it: the steel or precast section acts as the tension element and the masonry as the compression zone. The test specimen therefore includes the declared courses of masonry and mortar, cured before loading, and the standard also checks the initial shear bond between the prefabricated part and the masonry (EN 846-14).

    Yes. The standard allows the declared capacity to be derived from calculation to the relevant Eurocode, from testing to EN 846-9, or from calculation validated by tests. In practice steel and prestressed concrete lintels are often calculated, while composite and stone lintels are usually tested because the interaction with the masonry is hard to model.

    At least one specimen per span and section to be declared, and more where the manufacturer wants a statistical basis for the declared value. A common programme tests the shortest, longest and one intermediate span of a range. The laboratory confirms the exact numbers once the product range and declared bearing conditions are known.

    Related standards