Harmonised or product standard
EN 845-1 - Ancillary components for masonry - ties, tension straps, hangers and brackets
In short
EN 845-1 - Ancillary components for masonry - ties, tension straps, hangers and brackets. For wall ties, tension straps and joist hangers, Amstelfy covers tension and compression capacity, durability and dimensions in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 845-1 is the harmonised specification for the metal components that connect masonry leaves to each other and to the structure: cavity wall ties, tension and restraint straps, joist hangers and brackets. It sets out what the manufacturer declares for each product: the material and corrosion-protection reference taken from the table in the standard, the dimensions and tolerances, and the load-bearing performance relevant to the type, such as the tensile and compressive load capacity of a tie embedded in mortar joints, the shear capacity of shear and slip ties, the load-deflection behaviour of straps, and the vertical load capacity of hangers and brackets. Performance is established by type testing to the EN 846 series and maintained by factory production control. Declared values are characteristic figures derived from the test series by the statistical procedure in the standard.
Type testing and factory production control
Ties are tested in couplets: a tie is built into two masonry units with the mortar designation specified by the client, cured, then loaded in tension or compression at a controlled rate while displacement is recorded (EN 846-5; EN 846-6 for ties tested from one end only; EN 846-7 for shear and slip ties). Straps are tested for load capacity and deflection to EN 846-4, joist hangers to EN 846-8 and brackets to EN 846-10. The type-testing programme covers each material and coating reference, tie length and embedment that will be declared. Factory production control has to cover material certificates, coating mass or stainless grade verification, dimensional checks and periodic load tests at the frequencies set in the standard.
What the report states
The report gives, for each configuration, the individual failure loads, the mean and the characteristic (declared) value in kN, the load-displacement curves and the failure mode: tie pull-out, mortar failure, buckling, strap yielding or hanger deformation. Dimensions, material grade and coating are recorded against the material/coating reference claimed. The manufacturer carries the declared values into the Declaration of Performance and the product data sheet.
Where the result is required
EN 845-1 is cited whenever masonry ancillary components are CE marked in the EU and EEA, and the declared values are the input for wall-tie density and restraint design to Eurocode 6 (EN 1996-1-1) and its national annexes. Typical products are stainless steel and galvanised cavity ties for brick and block cavity walls, timber-frame ties, movement ties, straps restraining floors and roofs, and joist hangers built into masonry. The companion test methods are the EN 846 parts; lintels and bed joint reinforcement have their own specifications in the series.
What we assess
- tension and compression capacity
- durability
- dimensions
Products covered
- wall ties
- tension straps
- joist hangers
- brackets
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EN 845-5 - Ancillary components for masonry - lintels
- EN 845-7 - Ancillary components for masonry - bed joint reinforcement
- EN 13755 - Natural stone test methods - water absorption at atmospheric pressure
- EN 1925 - Natural stone test methods - water absorption coefficient by capillarity
- EN 771-6 - Specification for masonry units - natural stone masonry units
- EN 1341 - Slabs of natural stone for external paving
- EN 1469 - Natural stone products - slabs for cladding
- EN 12057 - Natural stone products - modular tiles