    EN 15651-4 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 4: sealants for pedestrian walkways

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 15651-4 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 4: sealants for pedestrian walkways. For construction sealants, Amstelfy covers tensile properties, adhesion/cohesion, elastic recovery, durability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 15651-4 covers sealants for movement joints in pedestrian walkways: balconies, terraces, external stairs, podium decks, station platforms and interior floors where people walk over the joint. The sealant must accommodate movement like a facade sealant and also resist foot traffic, standing water, de-icing salt and cleaning. The standard defines types PW-EXT, PW-INT and PW-EXT-INT with cold-climate CC variants, and uses movement classes derived from ISO 11600. Beyond the common sealant characteristics of tensile behaviour at maintained extension, elastic recovery, resistance to flow and loss of volume, part 4 adds conditioning that represents trafficked and exposed joints, notably adhesion and cohesion after immersion in salt water, and the cold-climate types are tested at a lower temperature. Conformity follows the type testing and factory production control pattern of the Construction Products Regulation.

    Type testing and factory production control

    Test specimens are sealant beads between mortar substrates, which represent the concrete and screed edges of walkway joints, or the substrates the manufacturer declares, cured by the conditioning method of the test standards. The programme runs the ISO sealant methods used across the series, ISO 8339 for tensile properties, ISO 8340 for maintained extension, ISO 9047 for adhesion and cohesion under temperature cycling, ISO 7389 for elastic recovery, ISO 7390 for flow and ISO 10563 for loss of volume, and adds the salt-water immersion before the adhesion and cohesion assessment. Exterior and cold-climate types are tested at the lower temperatures the standard sets. Reaction to fire is classified under EN 13501-1.

    What the report states

    The report gives for each characteristic the measured value and whether the requirement of the declared type and class is met: secant modulus in MPa, elastic recovery and loss of volume in per cent, flow in mm, and no failure of adhesion or cohesion after maintained extension, water and salt-water immersion and temperature cycling. The reaction-to-fire class is stated. The manufacturer carries the results into the Declaration of Performance and the CE marking.

    Where the result is required

    Polyurethane, hybrid polymer and some silicone sealants sold for balcony, terrace, podium deck and platform joints in the European Economic Area are CE marked under this part, with the AVCP system given in Annex ZA. Waterproofing and flooring contractors look for the PW type on data sheets when a joint is walked on. Joints trafficked by vehicles are outside the scope and are dealt with by other specifications. The same products are frequently also declared under part 1 for facade use.

    What we assess

    • tensile properties, adhesion/cohesion, elastic recovery, durability

    Products covered

    • construction sealants

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    A walkway sealant must satisfy the movement requirements of the facade part and in addition survive the conditions of a floor joint: immersion in water and salt water, foot traffic and more severe temperature exposure. Part 4 therefore uses the PW type designations and its own set of durability conditions, and a product declared only under part 1 should not be specified for a trafficked joint.

    No. The scope is limited to pedestrian walkways. Joints subject to vehicle wheels, fuel spillage or heavy mechanical cleaning fall outside the standard and are covered by other specifications for joint sealants in pavements and parking structures. Manufacturers often still use the part 4 data as supporting evidence for such uses.

    External walkways, balconies and platforms are treated with de-icing salts in winter and may stand in salt-laden water for long periods. Immersion in salt water before the adhesion and cohesion assessment shows that the sealant keeps its bond to the mortar substrate under those conditions, which plain water immersion does not fully represent.

    Related standards