Harmonised or product standard

    ISO 11600 - Building construction - jointing products - classification and requirements for sealants

    Certification · NAC-026-PPS

    In short

    ISO 11600 - Building construction - jointing products - classification and requirements for sealants. For sealants, Amstelfy covers classification and certification and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    ISO 11600 is the international classification and requirements standard for sealants used in building joints. It divides sealants into type G for glazing and type F for other building joints, and assigns classes by movement capability: 25, 20, 12.5 and 7.5 per cent of the joint width. Elastic classes are further split into low modulus (LM) and high modulus (HM) by the secant modulus at 100 per cent extension, with LM meaning a modulus of 0.4 MPa or less at 23 °C and 0.6 MPa or less at minus 20 °C; the 12.5 class is marked E for elastic or P for plastic behaviour according to elastic recovery, and 7.5 is plastic only. The EN 15651 series took its class system from this document.

    Type testing and factory production control

    Classification is demonstrated by a test programme on sealant specimens formed between the standard substrates, mortar, glass and anodised aluminium, cured by conditioning method A or B of the test standards. The methods are ISO 8339 for tensile properties and secant modulus, ISO 8340 for tensile properties at maintained extension, ISO 9046 and ISO 9047 for adhesion and cohesion at constant and variable temperature, ISO 7389 for elastic recovery, ISO 7390 for resistance to flow, ISO 10563 for change in mass and volume, ISO 10590 and ISO 10591 for behaviour after water immersion and ISO 11431 for glazing sealants. For certification, the reports are reviewed against the class requirements and factory production control is assessed and kept under surveillance.

    What the report states

    A certification decision under ISO 11600 states the sealant type and class, for example F 25 LM or G 20 HM, the substrates and conditioning method for which the classification holds, and the evidence relied upon. The underlying reports carry secant modulus in MPa, recovery and volume change in per cent, flow in mm and pass or fail statements for the extension and cycling tests. Manufacturers quote the classification on data sheets and in tender responses.

    Where the result is required

    ISO 11600 classes are quoted on sealant data sheets worldwide and are required in specifications for facade, glazing and precast joints in markets outside the European CE-marking system, including the Middle East, Africa, Asia-Pacific and parts of the Americas. Because EN 15651 adopted the same classes and test methods, a manufacturer with a complete EN 15651 type-test file can usually obtain ISO 11600 classification from the same evidence. Product certification against ISO 11600 is offered under the ISO/IEC 17065 scope.

    What we assess

    • classification and certification

    Products covered

    • sealants

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    It is on the ISO/IEC 17065 certification scope NAC-026-PPS; the related test methods are on the ISO/IEC 17025 testing scope.

    The distinction is made on the secant modulus at 100 per cent extension measured by ISO 8339: a low modulus sealant shows 0.4 MPa or less at 23 °C and 0.6 MPa or less at minus 20 °C, a high modulus sealant exceeds either value. Low modulus sealants are preferred where the substrate is weak, such as porous stone or render, because they transmit less stress to the joint edge.

    In most cases yes. EN 15651 took its classes and the underlying ISO test methods from ISO 11600, so the measured values map directly, provided the substrates and conditioning method match and the reports cover all characteristics required for the class. Any missing items, for example ISO 9046 at constant temperature, are added before the classification is confirmed.

    These are the lower movement classes. 12.5E is an elastic sealant with 12.5 per cent movement capability and the elastic recovery required for class E; 12.5P and 7.5P are plastic sealants, such as many acrylic and butyl products, that accommodate movement by flow rather than recovery. They are used in low-movement joints and for interior finishing rather than in facade movement joints.

    Related standards