Harmonised or product standard

    EN 15651-3 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 3: sealants for sanitary joints

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 15651-3 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 3: sealants for sanitary joints. For construction sealants, Amstelfy covers tensile properties, adhesion/cohesion, elastic recovery, durability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 15651-3 is the harmonised standard for sealants used in sanitary joints: around baths, showers, basins and tiled surfaces in bathrooms, kitchens and other wet rooms. These joints see little structural movement but constant wetting, cleaning and warm humid air, so the standard shifts the emphasis from movement capability to durability in wet service. It defines the sanitary type S and the classes XS1, XS2 and XS3, which combine the mechanical requirements with resistance to microbiological growth assessed by ISO 846. The essential characteristics include tensile properties at maintained extension after immersion in water, resistance to flow, loss of volume, the other sealant properties required for the class, and reaction to fire. Type testing and factory production control support the Declaration of Performance.

    Type testing and factory production control

    Sealant beads are applied between the standard substrates relevant to sanitary use, including glass, anodised aluminium and mortar, or the manufacturer's declared substrates, and cured by the conditioning method of the test standards. Mechanical testing uses the ISO sealant methods: ISO 8339 for tensile properties, ISO 7390 for resistance to flow, ISO 10563 for loss of volume, ISO 10590 for tensile properties at maintained extension after immersion in water, and ISO 7389 for elastic recovery where the class requires it. For the XS classes, cured sealant is exposed to a fungal culture under ISO 846 and the growth on the surface is rated. Factory production control focuses on batch consistency, control of the fungicide addition.

    What the report states

    The report lists each essential characteristic with its measured value and conformity statement: no failure after maintained extension following water immersion, loss of volume and, where required, elastic recovery in per cent, flow in mm, the fungal growth rating under ISO 846 that supports the claimed XS class, and the reaction-to-fire Euroclass. Where only type S without an XS class is claimed, the microbiological result is reported as no performance determined.

    Where the result is required

    The standard governs CE marking of silicone, hybrid and acrylic sanitary sealants sold in the European Economic Area, with the AVCP system given in Annex ZA, and the XS classes are what wholesalers, tiling contractors and bathroom manufacturers look for when specifying mould-resistant joints. Products marketed for both facade and sanitary use are tested under parts 1 and 3. The microbiological rating also supports product certification and hygiene claims in tender documents.

    What we assess

    • tensile properties, adhesion/cohesion, elastic recovery, durability

    Products covered

    • construction sealants

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Type S identifies a sealant intended for sanitary joints that meets the base mechanical and durability requirements. The XS classes add resistance to microbiological growth tested by ISO 846 together with the level of performance set for each class, so an XS designation tells the user the sealant has been shown to resist mould growth in wet-room conditions. Type S alone carries no such claim.

    Cured sealant specimens are inoculated with the fungal strains of ISO 846 and incubated under warm humid conditions for the period the method sets. Growth visible on the sealant surface is rated on the ISO 846 scale, and the rating must meet the limit for the claimed class. The test shows the effectiveness of the fungicide system built into the formulation.

    Sanitary joints spend much of their life wet, and water can soften a sealant or weaken its bond to glazed and enamelled surfaces. Holding specimens at maintained extension after immersion, as ISO 10590 does, shows that the seal keeps its adhesion and cohesion under those conditions rather than only when dry, which is the failure mode seen most often in bathrooms.

    Related standards