Harmonised or product standard
EN 15651-1 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 1: sealants for facade elements
In short
EN 15651-1 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 1: sealants for facade elements. For construction sealants, Amstelfy covers tensile properties, adhesion/cohesion, elastic recovery, durability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 15651-1 is the harmonised product standard for sealants used in non-structural movement joints of facade elements: joints between precast panels, around window frames, in masonry and curtain walling. It defines types by intended use, F-EXT-INT for exterior and interior joints, F-EXT-INT-CC for exterior use in cold climates and F-INT for interior joints, and classes taken from ISO 11600 such as 25LM, 25HM, 20LM, 20HM, 12.5E, 12.5P and 7.5P, which describe movement capability, modulus and elastic or plastic behaviour. Performance is shown by type testing of the essential characteristics, including tensile properties at maintained extension, adhesion and cohesion at variable temperature, elastic recovery, resistance to flow, loss of volume and reaction to fire, and by factory production control; the manufacturer then draws up a Declaration of Performance.
Type testing and factory production control
Type testing is run on sealant beads applied between standard substrates, mortar, glass or anodised aluminium, or on the substrates the manufacturer declares, cured by the conditioning method of the test standards and then subjected to the ISO methods the standard calls up: ISO 8339 for tensile properties, ISO 8340 for tensile properties at maintained extension, ISO 9047 for adhesion and cohesion under temperature cycling, ISO 7389 for elastic recovery, ISO 7390 for resistance to flow, ISO 10563 for loss of volume and ISO 10590 for performance after immersion in water. Reaction to fire follows EN 13501-1. Factory production control covers raw material control, batch testing of properties such as extrudability and skin-over time, and traceability.
What the report states
The test report states for each characteristic whether the sealant met the requirement of the declared type and class, with the measured values: secant modulus in MPa at the test temperatures, elastic recovery in per cent, flow in mm, loss of volume in per cent, and a no-failure statement for the maintained-extension and cycling tests. Reaction to fire is reported as a Euroclass. These feed the Declaration of Performance and the CE marking label.
Where the result is required
The standard applies to silicone, polyurethane, hybrid polymer and acrylic sealants sold for facade joints in the European Economic Area, which must carry CE marking under the Construction Products Regulation with the AVCP system given in Annex ZA. The same test file supports ISO 11600 classification for export markets, specifiers' approvals for curtain-wall and precast projects, and voluntary product certification. Glazing, sanitary and walkway uses are covered by parts 2, 3 and 4.
What we assess
- tensile properties, adhesion/cohesion, elastic recovery, durability
Products covered
- construction sealants
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EN 1372 - Adhesives - test method for adhesives for floor and wall coverings - peel test
- ISO 22631 - Adhesives - test methods for adhesives for floor and wall coverings - peel test
- EN 13893 - Resilient, laminate and textile floor coverings - dynamic coefficient of friction on dry floor surfaces
- ASTM D903 - Standard test method for peel or stripping strength of adhesive bonds
- ISO 37 - Rubber, vulcanized or thermoplastic - tensile stress-strain properties
- ISO 48 - Rubber - determination of hardness (Shore)
- ISO 48-2 - Rubber, vulcanized or thermoplastic - hardness between 10 IRHD and 100 IRHD
- ISO 48-4 - Rubber, vulcanized or thermoplastic - indentation hardness by durometer (Shore)