Harmonised or product standard

    EN 15651-2 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 2: sealants for glazing

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 15651-2 - Sealants for non-structural use in joints in buildings and pedestrian walkways - part 2: sealants for glazing. For construction sealants, Amstelfy covers tensile properties, adhesion/cohesion, elastic recovery, durability in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 15651-2 covers sealants used for non-structural glazing: weather seals and bedding between glass and frame in windows, doors and curtain walls. Compared with the facade part it narrows the classes to those with 25 or 20 per cent movement capability, 25LM, 25HM, 20LM and 20HM, because glazing joints must remain elastic, and it defines type G with a cold-climate variant G-CC. The essential difference lies in durability: glazing sealants are exposed to ultraviolet light transmitted through the glass and to condensation at the edge seal, so the standard requires adhesion and cohesion at maintained extension after exposure to heat, water and artificial light through glass in addition to the mechanical characteristics. Conformity is shown by type testing and factory production control under the Construction Products Regulation.

    Type testing and factory production control

    Sealant specimens are formed between glass and the second substrate, typically anodised aluminium or the frame material the manufacturer names, and cured by the conditioning method of the test standard. The programme includes tensile properties by ISO 8339, elastic recovery by ISO 7389, resistance to flow by ISO 7390, loss of volume by ISO 10563, tensile properties at maintained extension by ISO 8340 and after water immersion by ISO 10590, and the glazing-specific exposure of ISO 11431, in which extended specimens are cycled through heat, water and artificial light passing through the glass substrate before adhesion and cohesion are assessed. Cold-climate types add low-temperature testing. Reaction to fire is classified under EN 13501-1.

    What the report states

    The report records, characteristic by characteristic, the measured value and whether the requirement for the declared type and class is met: secant modulus in MPa, elastic recovery in per cent, flow in mm, loss of volume in per cent, and no failure of adhesion or cohesion after maintained extension, water immersion and the light-through-glass exposure. Reaction to fire is given as a Euroclass. The manufacturer transfers these to the Declaration of Performance.

    Where the result is required

    The standard is the CE-marking route for silicone and other elastic sealants marketed for glazing in windows, doors and curtain walls in the European Economic Area, with the AVCP system given in Annex ZA, and is referred to by window and facade fabricators when selecting weather seals. Many facade sealants are tested to parts 1 and 2 together so that a single product can be declared for both facade and glazing joints. Structural glazing is outside its scope and is assessed under EOTA guidance for structural sealant glazing kits.

    What we assess

    • tensile properties, adhesion/cohesion, elastic recovery, durability

    Products covered

    • construction sealants

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Part 2 is limited to the elastic classes 25LM, 25HM, 20LM and 20HM, uses glass as a mandatory substrate and adds the ISO 11431 exposure to heat, water and artificial light through glass. Part 1 covers a wider class range including plastic sealants and tests on mortar and aluminium as well as glass. Many silicone products are declared under both.

    No. It covers non-structural glazing where the sealant provides weather tightness and bedding but does not carry the glass. Structural sealant glazing systems, in which the sealant transfers wind and dead load, are assessed under the EOTA route for structural sealant glazing kits, with a different test programme and an ETA issued by a Technical Assessment Body.

    Specimens are held at a defined extension while being cycled through heat, immersion in water and ultraviolet radiation that reaches the sealant through the glass substrate, which is how a glazing seal is exposed in service. After the cycles the sealant must show no adhesive or cohesive failure beyond the limits in the standard, confirming that the bond to glass survives weathering.

    Related standards

    All Rubber, elastomers, sealants & adhesives testing