European Assessment Document
EAD 090062-01-0404 - Kits for external wall claddings mechanically fixed
In short
EAD 090062-01-0404 is the EOTA European Assessment Document for kits for external wall claddings mechanically fixed. Amstelfy Technical Solutions tests cladding kits against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): mechanical resistance, wind load, impact and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 090062-01-0404 covers kits for external wall claddings fixed mechanically to the wall. A kit always includes the cladding elements, sheets, planks, tiles, brick slips, boards, panels or cassettes of wood-based material, metal, natural or agglomerated stone, HPL, fibre cement, concrete, ceramic, plastic, cement-bonded board, thin metal composite sheet or WPC, together with their fixings, and optionally the subframe of profiles and brackets, a thermal insulation layer and ancillary components. Fixings are grouped in families from visible rivets and screws through undercut anchors, clips and rails to hook-on and concealed systems. Both ventilated and non-ventilated arrangements are covered, on masonry, concrete, timber or metal-frame substrates, including external ceilings and elements in contact with the ground. The kits are non-load-bearing; the assessment addresses the load path from element to subframe under wind, impact and point loads, water behaviour, durability of each component, thermal resistance of insulated non-ventilated kits, seismic parameters, fire and dangerous substances.
Assessment programme
Characterisation runs component by component: bending strength of elements, pull-through and shear resistance of fixings in the element, resistance of profiles, subframe fixings and brackets, vertical load capacity and, for ceiling use, creep over 2000 h. Wind load resistance is calculated and validated by chamber tests on assemblies built to the installation instructions; impact resistance uses hard-body energies of 1 J, 3 J and 10 J and soft-body energies of 10 J, 60 J, 100 J and 400 J, assigned to use categories. Watertightness of closed joints is tested under EN 12865. Durability covers hygrothermal behaviour, pulsating loads, freeze-thaw, immersion, dimensional stability, chemical, biological and UV resistance, corrosion and ageing of composite sheets. The client defines element materials, fixing families, subframe and insulation to be covered.
What the report states
Characteristic resistances of fixings, profiles and brackets as 5 % fractiles, the validated wind load resistance of each configuration, impact categories, watertightness pressure, retained properties after each durability exposure, corrosion classes and, where relevant, the seismic out-of-plane period and acceleration and in-plane drift are reported clause by clause, with the thermal resistance of insulated kits. The TAB uses the report to fix the conditions of use, spans and design loads in the ETA.
Where the result is required
Facade system houses, panel manufacturers, metal cassette producers and suppliers of complete rainscreen packages obtain ETAs under this EAD to CE mark the kit and to publish design data for the whole assembly rather than the element alone; EAD 090019 refers to it for rendered board kits. Reports also underpin project-specific approvals for high-rise refurbishment, extensions of an ETA to new element materials or fixing families, and voluntary certification of cladding kits under ISO/IEC 17065 where owners require third-party surveillance of production.
What we assess
- mechanical resistance
- wind load
- impact
- durability
Products covered
- cladding kits
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 040083-01-0404 - External Thermal Insulation Composite Systems (ETICS) with renderings
- EAD 040016-01-0404 - Glass fibre mesh for reinforcement of cementitious or cement-based renderings
- EAD 090019-01-0404 - Kits for external wall claddings of expanded glass granulates boards, magnesium oxide boards or other mineral boards with rendering applied on site
- EAD 210046-00-1201 - Thin metal composite sheet
- EN 14509 - Self-supporting double skin metal faced insulating panels - factory made products