European Assessment Document

    EAD 090019-01-0404 - Kits for external wall claddings of expanded glass granulates boards, magnesium oxide boards or other mineral boards with rendering applied on site

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 090019-01-0404 is the EOTA European Assessment Document for kits for external wall claddings of expanded glass granulates boards, magnesium oxide boards or other mineral boards with rendering applied on site. Amstelfy Technical Solutions tests ventilated cladding kits against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): mechanical resistance of panels and fixings, wind suction, impact resistance and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 090019-01-0404 covers kits in which boards of expanded glass granulate, magnesium oxide, fibre cement, fibre-reinforced gypsum or cement-bonded material are fixed mechanically to a metal or timber subframe and finished on site with a reinforced rendering system of base coat, glass fibre mesh, optional key coat and finishing coat. The kit may include thermal insulation, a breather membrane and ancillary components, and it is assessed for ventilated rain-screen use and for non-ventilated use; the EOTA title names the board types rather than the mechanically fixed panels of EAD 090062, to which this EAD refers for many shared characteristics. Essential characteristics are reaction to fire and facade fire behaviour, water absorption and vapour permeability, bond strength of the rendering to the board, bending strength of the boards, impact resistance, wind load and point load resistance of boards, fixings, profiles and brackets, hygrothermal and freeze-thaw behaviour, dimensional and flatness stability under humidity, thermal expansion and corrosion.

    Assessment programme

    Board characterisation follows the material standards: bending strength on at least five specimens, capillary water absorption at 3 min, 1 h and 24 h, dimensional and flatness changes under humidity and, for magnesium oxide boards, core adhesion at high temperature. The rendering is applied to boards and tested for bond strength, with average and minimum values and rupture type recorded before and after conditioning. Rendered assemblies on the subframe undergo the hygrothermal cycles of the EAD annex and, when the 24 h capillary absorption reaches 0.5 kg/m², freeze-thaw cycles, followed by renewed bond and impact tests. Wind load, pull-through, profile, bracket and subframe fixing resistance and point loads follow the methods taken over from EAD 090062. The client defines board types, subframe family and the uses claimed.

    What the report states

    The report lists board properties against the material standard, bond strengths in kPa with rupture percentages and the after-to-before ratio for each conditioning, observations from the hygrothermal and freeze-thaw cycles, impact results per energy, characteristic resistances of fixings, profiles and brackets as 5 % fractiles, and the water absorption, vapour permeability and dimensional stability data. Mechanical results are rounded down as the EAD requires. The TAB uses the report for the ETA.

    Where the result is required

    Rendered board kits give a seamless rendered appearance on a ventilated or non-ventilated subframe where ETICS cannot be bonded, for timber-frame and metal-frame buildings, refurbishment over uneven walls and curved facades. The ETA under this EAD is the CE marking route for such kits; the AVCP system is 2+, with system 1, 3 or 4 for reaction to fire depending on the class and production. The same test data serve national approvals and voluntary product certification under ISO/IEC 17065 for owners who ask for third-party surveillance.

    What we assess

    • mechanical resistance of panels and fixings
    • wind suction
    • impact resistance
    • durability

    Products covered

    • ventilated cladding kits

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    Both end in a rendered surface, but in an ETICS the render is carried by insulation bonded or anchored to the wall, whereas here it is carried by a board screwed, nailed or riveted to a subframe, with the insulation optional and a ventilated cavity possible. The board, its fixings and the subframe therefore need the mechanical assessment, while the rendering tests resemble those of ETICS.

    Expanded glass granulate boards, magnesium oxide boards, fibre cement boards, fibre-reinforced gypsum boards and cement-bonded boards, each characterised by its own material standard and, for magnesium oxide, by an additional check of core adhesion at high temperature. Panels that remain visible without render, such as HPL or metal cassettes, are assessed under EAD 090062 instead.

    No. It is triggered by the capillary water absorption of the base coat or rendering system: when the mean value after 24 h is 0.5 kg/m² or more, rendered specimens undergo the freeze-thaw cycles of the EAD and are then retested for bond and impact. Low-absorption renders are deemed resistant on the basis of the absorption result alone.

    Related standards

    All ETICS, cladding kits, sandwich panels & building envelope testing