Harmonised or product standard

    EN 131-4 - Ladders - part 4: single or multiple hinge-joint ladders

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 131-4 - Ladders - part 4: single or multiple hinge-joint ladders. For portable ladders, Amstelfy covers strength, deflection, torsion and durability tests in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 131-4 adds the requirements for ladders whose stiles are divided by one or more hinge joints, so that the same product can be set up as a leaning ladder, a standing ladder, a work platform or a stairway ladder. The hinges are the safety-critical element: each must lock positively in every position of use, the locked state must be evident to the user and unintended release under load or during handling must be prevented. The part specifies hinge design and locking requirements, the configurations in which the ladder must be tested and how the general tests of EN 131-2 are applied, with the strength load placed above the uppermost hinge pair, together with hinge-specific durability under repeated opening, closing and locking. Dimensions and the widened base rule for leaning use follow EN 131-1.

    Type testing and factory production control

    The ladder is first checked for the configurations the manufacturer declares and for the locking action, indicator and release mechanism of each hinge. Strength, bending, lateral deflection and torsion tests of EN 131-2 are then performed in each configuration, with the load positioned as EN 131-4 prescribes so that the hinges are in the loaded zone. Hinge durability consists of repeated cycles of unlocking, folding and relocking followed by a repeat of the strength test. Platform configurations are tested with the platform specified by the manufacturer, which must be supplied with the ladder where the standard requires it. Professional and non-professional class loads and cycle counts follow EN 131-2.

    What the report states

    The report records, per configuration, the loads applied, deflections and residual deformation, the behaviour of the hinges during loading and after cycling, and any release, play or cracking observed. The ladder is classed professional or non-professional, and the configurations found to conform are listed so that the user instructions and pictograms can be checked against them under EN 131-3.

    Where the result is required

    Articulated multi-purpose ladders are among the most widely sold consumer and trade ladders in Europe, and their hinges are a recurrent subject of market surveillance recalls. Manufacturers and importers use EN 131-4 testing to qualify new hinge designs and lock mechanisms, retailers require it before listing, and certification schemes combine it with EN 131-2 and EN 131-3 to cover the complete product. Telescopic ladders with hinges are tested under EN 131-6 with the Part 4 hinge requirements applied.

    What we assess

    • strength, deflection, torsion and durability tests

    Products covered

    • portable ladders

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Yes. Each configuration the manufacturer declares, leaning, standing, platform or stairway, loads the hinges differently, so the strength and torsion tests are repeated in each. Configurations not tested must not be shown in the instructions or pictograms. This is why a multi-purpose ladder programme takes longer than a single-type ladder.

    Typical findings are locks that can be released while loaded, indicators that show a locked state before the pin is fully engaged, excessive play after the durability cycles that increases deflection, and cracking of the hinge plates or rivets in the strength test. A missing platform for the work-platform configuration is a documentary failure.

    Yes, when the extended length in the leaning configuration exceeds 3 m. EN 131-1 applies the same rule to hinge-joint ladders as to ordinary leaning ladders, with the stabiliser length depending on ladder length, and EN 131-4 requires the ladder to be tested with it fitted.

    Related standards

    All Scaffolding, temporary works equipment & ladders testing