Harmonised or product standard

    EN 74-2 - Couplers, spigot pins and baseplates - special couplers

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 74-2 - Couplers, spigot pins and baseplates - special couplers. For special couplers, Amstelfy covers slip and failure tests in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 74-2 covers the couplers that fall outside the four standard types of Part 1 but still connect to a 48.3 mm steel or aluminium tube on at least one side. It specifies screw and wedge half couplers, which are welded or bolted to other components and clamp a single tube; sleeve couplers with shear studs, which engage holes near the tube ends; and right-angle and swivel reduction couplers, which join a 48.3 mm tube to a tube of another diameter such as 38.0, 42.4, 60.3, 63.5 or 76.1 mm. Half couplers are classified A or B; sleeve couplers with shear studs and reduction couplers are unclassified and must simply meet the specified values. Riveted half couplers used inside prefabricated scaffold members are excluded.

    Type testing and factory production control

    Specimens are mounted on reference tubes of the diameters named in the standard, with screw couplers tightened to 50 Nm and wedge couplers hammered home with a 500 g hammer. Half couplers are loaded in slipping, failure, pull-apart and shear, and their indentation of the tube is measured; class B half couplers are additionally tested for bending moment and stiffness about two axes. Sleeve couplers with shear studs are tested for failure force and bending moment, with the stud hole position and diameter checked beforehand. Reduction couplers undergo slipping, failure and indentation tests, with a pull-apart test added for the right-angle type. Each test uses a set of specimens evaluated statistically.

    What the report states

    The report gives the characteristic slipping, failure, pull-apart and shear forces in kN, bending moment in kNm and bending stiffness in kNm/rad where applicable, and the indentation depth in mm at the specified check load. Values are compared with the limits for the coupler type and class. Conforming half couplers are marked with their class; reduction and shear-stud sleeve couplers are marked as conforming to the standard.

    Where the result is required

    Special couplers appear wherever system scaffolds, access towers or falsework meet loose tubes: half couplers on prefabricated frames and brackets, reduction couplers that tie 48.3 mm tubes into larger-diameter falsework legs or smaller handrail tubes, and shear-stud sleeves for tension-capable end joints. Designers working to EN 12811-1 or EN 12813 need the characteristic values to justify these connections, and manufacturers of prefabricated components use the test results in their type documentation.

    What we assess

    • slip and failure tests

    Products covered

    • special couplers

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Part 1 covers the right-angle, swivel, parallel and sleeve couplers that join two 48.3 mm tubes. Part 2 covers half couplers fixed to other components, sleeve couplers with shear studs and reduction couplers that join a 48.3 mm tube to a tube of a different diameter. If your product clamps only one tube, it is almost always a Part 2 product.

    The shear test loads the half coupler across its attachment to the component it is fixed to, rather than along the clamped tube, and checks the ultimate shear capacity of the connection. It is specific to half couplers because their weld or bolt attachment carries loads that a two-tube coupler never sees.

    Yes. Reduction couplers are tested on reference tubes of both diameters, so the client should state the second-side diameter and wall thickness the coupler is designed for. Reference tubes of 48.3 mm are standard laboratory stock; the second diameter is procured to the yield strength range of the standard or sent with the couplers.

    Related standards

    All Scaffolding, temporary works equipment & ladders testing