Harmonised or product standard

    EN 12810-2 - Facade scaffolds made of prefabricated components - particular methods of structural design

    Testing · NAC-037-TL

    In short

    EN 12810-2 - Facade scaffolds made of prefabricated components - particular methods of structural design. For prefabricated facade scaffolds, Amstelfy covers load tests of components and assemblies supporting structural design in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 12810-2 sets out the particular methods of structural design for facade scaffold systems made of prefabricated components, complementing the product specification in EN 12810-1 and the general performance requirements of EN 12811-1. It describes how the system configurations declared by the manufacturer are analysed: which load combinations and imperfections apply, how anchor forces to the facade are determined, how wind acts on clad and unclad scaffolds, and how the non-linear behaviour of spigot joints, ledger-to-standard connections and couplers is represented. Where that behaviour cannot be calculated reliably, the standard directs the designer to tests: component resistances and connection stiffnesses are determined by load testing to EN 12811-3 and entered into the model as characteristic values. The outcome is the structural justification behind the manufacturer's instruction manual.

    Type testing and factory production control

    The laboratory work under this standard is test-assisted design. Typical programmes include moment-rotation tests on ledger-to-standard connections, axial and bending tests on spigot joints between standards, load tests on platform units and lattice girders, and tests on anchor components and base jacks. Specimens are production components assembled as in service; the test set-up, loading sequence, measurement of deformation and looseness, and the number of specimens follow EN 12811-3. Material properties of the tested parts are measured so that results can be converted to nominal values. The client specifies the system configurations, bay lengths, lift heights and cladding conditions to be covered, because the connection stiffnesses must match the configurations analysed.

    What the report states

    Reports present characteristic resistances in kN or kNm and stiffness values in kN/mm or kNm/rad for each connection or component, with the load-deformation curves and the statistical evaluation. These values are input data for the structural analysis of the system configurations in EN 12810-2 and for the capacity statements in the instruction manual, not pass or fail results in themselves.

    Where the result is required

    Facade scaffold manufacturers use EN 12810-2 analyses, supported by tests, to justify the load class, bay length, height and tie pattern of every configuration they publish, which national approval schemes and client specifications expect to see. The same stiffness values are reused when a system is extended with new components or when a contractor needs a non-standard configuration checked. Hire companies and inspection bodies rely on the resulting documentation when accepting a system for use on site.

    What we assess

    • load tests of components and assemblies supporting structural design

    Products covered

    • prefabricated facade scaffolds

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    EN 12811-1 states the performance a scaffold must achieve and the general design rules. EN 12810-2 explains how to model a prefabricated facade system to prove that performance, including which connection properties must come from tests. In practice EN 12811-1 defines the targets and EN 12810-2 defines the analysis and the test-derived inputs.

    The ledger-to-standard joint, the spigot or sleeve joint between standards and the connection of guardrail and diagonal braces are the usual candidates, because their rotational and axial behaviour is non-linear and governs the buckling length of the standards. Platforms and anchor assemblies are tested for resistance rather than stiffness.

    Connection tests are independent of bay length, so one set of joint tests serves all configurations that use the same components. Platform and girder tests are length-specific and are repeated for each span the manufacturer wishes to declare. The configurations in the instruction manual must all be covered by the analysed cases.

    Related standards

    All Scaffolding, temporary works equipment & ladders testing