Harmonised or product standard

    EN 12813 - Temporary works equipment - load bearing towers of prefabricated components

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 12813 - Temporary works equipment - load bearing towers of prefabricated components. For load bearing towers, Amstelfy covers load tests in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 12813 gives the particular methods of structural design for load-bearing towers assembled from prefabricated steel or aluminium components, the shoring towers used in falsework to carry slab and beam formwork. It explains how to determine the stiffness and resistance data of a tower type for vertical load, with or without horizontal loads and with the top restrained or free, using first-order or second-order analysis supported by tests. Detail tests establish the behaviour of the joints, spigots, jacks and frames that the model cannot predict reliably, and a full-scale global test on a complete tower confirms that the model is accurate and errs on the safe side. Towers built from loose tubes and couplers are outside the scope and are designed under EN 12812, which also supplies the loads and material rules that EN 12813 assumes.

    Type testing and factory production control

    Detail tests are made on the components that govern tower behaviour: ledger-to-standard or frame joints in bending and rotation, spigot or sleeve connections between lifts, base and head jacks at the extensions used in practice, and bracing connections. Global tests load a complete tower, usually several lifts high and with the jacks extended to the declared maximum, through a loading beam at the head until failure, with eccentricity and top restraint as specified for the case analysed. Deflections at each lift and the jack rotation are measured. Test procedures, specimen numbers and material tests follow EN 12811-3, and the results are compared with the calculated resistance for the same configuration as the standard requires.

    What the report states

    Reports give the joint stiffnesses and detail resistances used in the model, the failure loads and load-deflection records of the global tests and the comparison between calculated and experimental resistance for each case. The manufacturer uses them to publish load tables of the tower type for the falsework designer, with the tower height, jack extension, bracing and head restraint conditions to which each capacity applies.

    Where the result is required

    Shoring towers to EN 12813 support slab formwork, bridge decks and heavy transfer structures where props to EN 1065 are insufficient. Falsework designers working to EN 12812 need the published stiffness and resistance data, and contractors and national approval schemes expect them to be test-verified. Manufacturers use the programme when launching a tower system, extending it to new jack lengths or frame heights, or qualifying a second production source for its components.

    What we assess

    • load tests

    Products covered

    • load bearing towers

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    The global test checks the whole design model rather than individual parts. A complete tower is loaded to failure in a configuration that was also calculated, and the measured resistance must confirm that the model is accurate and on the safe side. It catches interactions between jacks, joints and bracing that detail tests cannot show.

    Each connection type whose stiffness or strength enters the model needs its own series: the lift joint, the ledger or frame connection, the jack-to-standard interface and the bracing attachment are typical. The number per series follows the statistical rules of EN 12811-3 and the scatter observed in the first specimens.

    No. The standard covers towers made of prefabricated components with defined joints. Shoring assembled from loose tubes and couplers is designed under EN 12812 using the coupler classes from EN 74-1, because its connection behaviour depends on site assembly rather than on a tested system.