Harmonised or product standard

    EN 1004 – Mobile access tower testing

    Mobile access and working towers made of prefabricated elements

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 1004 - Mobile access and working towers made of prefabricated elements. For mobile access towers, Amstelfy covers stability, strength and rigidity tests in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 1004-1 is the product standard for mobile access and working towers assembled from prefabricated elements and standing on castors or base plates, with platform heights up to 12 m indoors and 8 m outdoors. It replaced EN 1004:2004 and sits alongside EN 1004-2, which covers the instruction manual. Towers are classified by load class, taken from the EN 12811-1 platform classes, by access class according to the stairway, stair-ladder, inclined or vertical ladder provided, and by height class, and are described by a designation that also states the configurations covered. The standard defines materials, platform and guardrail requirements, castor and brake performance, stabilising methods such as outriggers and ballast, the horizontal and vertical loads to be resisted and the rigidity and stability a tower must show under them. Scaffolds to EN 12810-1 and EN 12811-1 are outside its scope.

    Type testing and factory production control

    A full-height tower is assembled in each configuration to be declared, with the stabilisers, ballast or ties specified in the manual. The rigidity test applies a horizontal load at platform level and records the displacement, which must stay within the limit of the standard. Stability is verified by calculation or test for the combination of working load, horizontal load and wind, for indoor and outdoor configurations separately. Strength tests on platforms, frames, braces, trapdoors and castors follow EN 12811-3, with castors also checked for braking on a slope and for load capacity. Dimensions of platforms, access openings, rung spacing and side protection are measured against the requirements. The instruction manual is reviewed against EN 1004-2 as part of certification.

    What the report states

    The report records the displacement under the horizontal rigidity load, the stability margin for each configuration and the resistance of each component, with pass or fail against the limits of the standard. The tower receives its designation with load class, access class and height class and the maximum platform heights indoors and outdoors, which must match the manual. Certification under the ISO/IEC 17065 scheme covers EN 1004-1.

    Where the result is required

    Aluminium and steel towers for finishing trades, facility maintenance, installation work and events are sold throughout Europe under the EN 1004-1 designation, and rental fleets and site safety rules in most countries accept only towers that show it. The tests also support national schemes that require third-party evidence for tower systems. Manufacturers adding a new platform length, stair unit or outrigger to an existing system repeat the affected rigidity and strength tests rather than the full programme.

    What we assess

    • stability, strength and rigidity tests

    Products covered

    • mobile access towers

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Outdoors the tower must resist wind in addition to the working and horizontal loads, which reduces the height at which stability can be shown with the same base, outriggers and ballast. The standard therefore caps outdoor platform height at 8 m against 12 m indoors, and the manual states both for each configuration.

    The assembled tower is loaded horizontally at platform level and the resulting displacement is measured. The limit ensures that the tower feels stable to the user and that second-order effects remain small; a tower that passes the strength checks can still fail rigidity if its frame joints are loose or its bracing pattern is weak.

    EN 1004-2 sets out the content of the instruction manual, including assembly sequences, configurations, ballast and tie requirements. The product certification is against EN 1004-1, but the manual is reviewed because the tested configurations, heights and stabilising methods must be the ones the user is instructed to build.