Harmonised or product standard

    EN 13374 – Edge protection testing

    Temporary edge protection systems - product specification, test methods

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 13374 - Temporary edge protection systems - product specification, test methods. For edge protection systems, Amstelfy covers static and dynamic loading (classes A, B, C) in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 13374 specifies temporary edge protection systems used during construction to prevent falls from roofs, slab edges and openings. Systems are classified by the hazard they must control. Class A is for surfaces inclined up to 10 degrees and must resist a person leaning or walking into it, verified under static loads. Class B must also arrest a person sliding down a slope of up to 30 degrees, or up to 60 degrees where the fall height is below 2 m, and is verified by a low-energy dynamic test. Class C must contain a person sliding down slopes between 30 and 45 degrees, or up to 60 degrees where the fall height is below 5 m, and is verified by a high-energy dynamic test. The standard also sets guardrail heights, maximum gaps, toe board requirements and deflection limits.

    Type testing and factory production control

    A representative length of the system is erected on a test rig that reproduces the intended fixing, whether clamped to a slab edge, bolted, counterweighted or braced from the roof, at the slope for which the class is claimed. Static tests apply horizontal and vertical point loads to the guardrails, posts and toe board and record deflection and residual deformation. For class B the dynamic test swings a soft test body into the guardrail at the energy defined by the standard; for class C a cylindrical rolling body is released down the inclined surface into the system. Gaps, infill openings and guardrail height are measured before and after loading. The client specifies the class, slope range, post spacing and fixing.

    What the report states

    The report records the loads applied, the measured deflections against the limits, residual deformations and the behaviour of each dynamic test: whether the test body was retained, which components yielded or fractured and whether any part detached. Guardrail height and gap measurements are listed against the class requirements. The system is classified A, B or C for the tested slope range, post spacing and fixing method, and the marking is checked.

    Where the result is required

    Edge protection to EN 13374 is required on building sites across Europe by national work-at-height regulations, and contractors select the class from the roof pitch and fall height of each job. Manufacturers of clamp-on, counterweighted and roof-anchored systems, as well as precast and steelwork suppliers who build edge protection into their elements, need class evidence for their product documentation. Test results also support product certification and periodic re-qualification when post spacing or infill materials change.

    What we assess

    • static and dynamic loading (classes A, B, C)

    Products covered

    • edge protection systems

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    Start from the slope of the surface and the fall height. Up to 10 degrees class A is sufficient. Up to 30 degrees, or up to 60 degrees with a fall height under 2 m, class B is required. Between 30 and 45 degrees, or up to 60 degrees with a fall height under 5 m, class C applies. Beyond these limits the standard does not cover the application.

    Class B simulates a person stumbling or sliding into the guardrail on a moderate slope, so a soft body is swung into the rail at a defined energy. Class C simulates a person sliding down a steep roof at speed, so a heavier cylindrical body rolls down the test slope into the system and the energy is correspondingly higher.

    Yes. The system is classified for the fixing it was tested with, because counterweights, slab clamps and roof anchors transfer the loads differently. A system tested only with slab clamps cannot be marked for a counterweighted configuration without an additional test or a documented structural justification accepted under the standard.

    Related standards