Harmonised or product standard
EN 13374 – Edge protection testing
Temporary edge protection systems - product specification, test methods
In short
EN 13374 - Temporary edge protection systems - product specification, test methods. For edge protection systems, Amstelfy covers static and dynamic loading (classes A, B, C) in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.
What the standard covers
EN 13374 specifies temporary edge protection systems used during construction to prevent falls from roofs, slab edges and openings. Systems are classified by the hazard they must control. Class A is for surfaces inclined up to 10 degrees and must resist a person leaning or walking into it, verified under static loads. Class B must also arrest a person sliding down a slope of up to 30 degrees, or up to 60 degrees where the fall height is below 2 m, and is verified by a low-energy dynamic test. Class C must contain a person sliding down slopes between 30 and 45 degrees, or up to 60 degrees where the fall height is below 5 m, and is verified by a high-energy dynamic test. The standard also sets guardrail heights, maximum gaps, toe board requirements and deflection limits.
Type testing and factory production control
A representative length of the system is erected on a test rig that reproduces the intended fixing, whether clamped to a slab edge, bolted, counterweighted or braced from the roof, at the slope for which the class is claimed. Static tests apply horizontal and vertical point loads to the guardrails, posts and toe board and record deflection and residual deformation. For class B the dynamic test swings a soft test body into the guardrail at the energy defined by the standard; for class C a cylindrical rolling body is released down the inclined surface into the system. Gaps, infill openings and guardrail height are measured before and after loading. The client specifies the class, slope range, post spacing and fixing.
What the report states
The report records the loads applied, the measured deflections against the limits, residual deformations and the behaviour of each dynamic test: whether the test body was retained, which components yielded or fractured and whether any part detached. Guardrail height and gap measurements are listed against the class requirements. The system is classified A, B or C for the tested slope range, post spacing and fixing method, and the marking is checked.
Where the result is required
Edge protection to EN 13374 is required on building sites across Europe by national work-at-height regulations, and contractors select the class from the roof pitch and fall height of each job. Manufacturers of clamp-on, counterweighted and roof-anchored systems, as well as precast and steelwork suppliers who build edge protection into their elements, need class evidence for their product documentation. Test results also support product certification and periodic re-qualification when post spacing or infill materials change.
What we assess
- static and dynamic loading (classes A, B, C)
Products covered
- edge protection systems
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EN 39 - Loose steel tubes for tube and coupler scaffolds
- EN 74-1 - Couplers, spigot pins and baseplates for use in falsework and scaffolds - couplers for tubes
- EN 74-2 - Couplers, spigot pins and baseplates - special couplers
- EN 12810-2 - Facade scaffolds made of prefabricated components - particular methods of structural design
- EN 12811-3 - Temporary works equipment - load testing
- EN 12811-1 - Temporary works equipment - scaffolds - performance requirements and general design
- EN 1065 - Adjustable telescopic steel props - product specifications, design and assessment by calculation and tests
- EN 1263-1 - Temporary works equipment - safety nets - safety requirements, test methods