Harmonised or product standard

    EN 10034 - Structural steel I and H sections - tolerances on shape and dimensions

    Testing · NAC-037-TL

    In short

    EN 10034 - Structural steel I and H sections - tolerances on shape and dimensions. For steel sections, Amstelfy covers dimensional tolerances in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 10034 defines the permitted deviations of hot-rolled structural steel I and H sections from their nominal dimensions. The nominal dimensions come from the section range standards, now EN 10365 for the IPE, HE, HL, HD and related series, and the steel grade from EN 10025, so EN 10034 tells an inspector how far an actual beam may depart from the drawing. It sets tolerances on section height, flange width, web and flange thickness, out-of-square of the flanges, off-centre position of the web, straightness over the length, and on mass and length, with limits graded by section size. In the laboratory it is a measurement procedure rather than a test: sections used in test rigs, in temporary works components and in products submitted for testing are checked against it before their nominal section properties are relied upon.

    Type testing and factory production control

    Sections are measured at positions along the length defined by the standard, away from the cut ends where rolling and cutting affect the profile. Height and flange width are taken with calipers or a large micrometer, web and flange thickness at the specified points across the flange, out-of-square with a square and feeler gauges or a profile gauge, and web eccentricity from the difference between the two flange overhangs. Straightness is measured as the maximum deviation from a taut line or straightedge over the length, in both axes. Mass per metre is calculated from the weighed length. All instruments carry traceable calibration and the results are compared with the tolerance for the section's nominal height.

    What the report states

    The report lists each measured dimension with the nominal value, the permitted plus and minus deviation and the actual deviation, states whether the section conforms, and records the measuring positions. Where a section is used as a test rig member or a loaded component, the report notes the actual section so that the calculated resistance can be based on measured rather than nominal dimensions.

    Where the result is required

    Fabricators and steel stockholders refer to EN 10034 for receiving inspection of beams and columns under EN 1090 execution requirements, and manufacturers of temporary works such as shoring beams, trench support frames and loading platforms use it to confirm the sections built into their products. Testing laboratories apply it when a section forms part of a test specimen or of the reaction frame, because dimensional deviation feeds directly into the section properties used in evaluating results.

    What we assess

    • dimensional tolerances

    Products covered

    • steel sections

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    No. It gives only the permitted deviations. The nominal height, width, thicknesses and section properties come from the section range standards such as EN 10365, and the mechanical properties from the steel grade standard. An inspection therefore needs the section designation and the applicable range standard to set the nominal values.

    Flange thickness and section height govern the second moment of area and so the bending stiffness and strength; web off-centre and out-of-square flanges introduce eccentricity and affect connections; straightness influences buckling. The report presents all of them, but the structural engineer usually looks first at thickness and straightness.

    It can, provided the actual dimensions are recorded and the evaluation uses them instead of nominal values. In a loaded test rig an undersize section reduces the available capacity, so the deviation is also checked against the rig design. For a product under test the deviation is a finding in its own right.

    Related standards