Harmonised or product standard

    EN 12385-2+A1 - Steel wire ropes - safety - definitions, designation and classification

    Testing · NAC-037-TLCertification · NAC-026-PPS

    In short

    EN 12385-2+A1 - Steel wire ropes - safety - definitions, designation and classification. For steel wire ropes, Amstelfy covers classification in its ISO/IEC 17025-accredited laboratory (NAC-037-TL) and acts as ISO/IEC 17065-accredited product certification body (NAC-026-PPS) for this standard. Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 12385-2 is the terminology and classification part of the wire rope safety series. It defines the terms for rope components and properties, from wire, strand, core and lay to minimum breaking force and rope grade, and it sets out the designation system by which a rope is unambiguously described: nominal diameter, construction and class, core type, rope grade, surface finish and the direction and type of lay. It groups constructions into classes, such as the 6 x 19 or 6 x 36 classes, so that ropes with similar numbers of outer strands and wires per strand can share requirements and breaking force factors in the product parts. The designation determines which requirements of EN 12385-4 and the other product parts apply, and a wrong designation leads to the wrong minimum breaking force and the wrong acceptance criteria.

    Type testing and factory production control

    In laboratory work the standard is used to identify and describe the rope before any test. The construction is established by counting strands and wires, examining the strand pattern and the core, and measuring lay direction and lay length; the diameter is measured as the circumscribed circle at several positions; the finish is recorded as bright or zinc coated and the rope grade is taken from the manufacturer's certificate and checked by wire tensile tests. From these the full designation is written and the rope class is assigned, which fixes the breaking force factor and the applicable requirements in the product part. Discrepancies between the delivered rope and the ordered designation are reported before breaking force testing proceeds.

    What the report states

    The report states the designation of the rope as established by examination, the class to which it belongs, the measured lay length and lay direction, the core type and finish, and notes any difference from the designation on the certificate or packaging. This description is carried into breaking force reports under EN 12385-4 and termination tests under EN 13411-3 so that results are traceable to a defined product.

    Where the result is required

    Every rope specification, order, certificate and test report in Europe uses the EN 12385-2 designation, and the classification governs which table of minimum breaking forces applies in EN 12385-4 for cranes, hoists and general lifting, in EN 12385-5 for lifts and in EN 12385-10 for spiral ropes. Rope manufacturers, sling makers, crane builders and inspection engineers rely on it to compare ropes, to specify replacements and to check that a rope delivered matches the one ordered.

    What we assess

    • classification

    Products covered

    • steel wire ropes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL and on the ISO/IEC 17065 certification scope NAC-026-PPS.

    The first lower-case letter gives the direction of lay of the wires in the strand and the capital letter the direction of lay of the strands in the rope. Different letters, as in sZ, denote ordinary lay; the same letters, as in zZ, denote Lang's lay. Lay type affects flexibility, wear and rotation behaviour.

    Ropes with the same number of strands and a similar count of wires per strand behave alike in strength, and the product parts assign them common breaking force factors and requirements. The class lets a user accept several constructions, for example 6 x 25 Filler or 6 x 26 Warrington-Seale within the 6 x 19 class, while keeping the same minimum breaking force.

    No. It provides definitions, the designation system and the classification. Requirements such as minimum breaking force, diameter tolerance and wire properties, and the tests that verify them, are in EN 12385-1 for general requirements and in the product parts, for example EN 12385-4 for stranded ropes used in general lifting.

    Related standards

    All Steel wire, wire ropes & lifting accessories testing