Harmonised or product standard

    EN 10264-1 - Steel wire and wire products - steel wire for ropes - general requirements

    Testing · NAC-037-TL

    In short

    EN 10264-1 - Steel wire and wire products - steel wire for ropes - general requirements. For steel wire for ropes, Amstelfy covers tensile strength, torsion, coating in its ISO/IEC 17025-accredited laboratory (NAC-037-TL). Reports and certificates are written for use in CE marking files, Declarations of Performance and third-party approvals across Europe.

    What the standard covers

    EN 10264-1 sets the general requirements common to all steel wire for ropes, with the product-specific grades given in Part 2 for non-alloy wire for general applications, Part 3 for round and shaped wire for high-duty ropes and Part 4 for stainless steel wire. Part 1 defines the terms, the designation of wire by diameter, tensile strength grade, surface finish and shape, the dimensional tolerances on diameter and out-of-roundness, the surface finishes from bright drawn to the zinc and zinc-alloy coating classes, and the general conditions for inspection, sampling and documentation. It also names the test methods: tensile strength and, where required, elongation to EN 10218-1, the simple torsion and reverse bend tests that reveal the ductility a wire needs to survive stranding and service bending, the wrapping test for coating adherence and the coating mass determination.

    Type testing and factory production control

    Test pieces are cut from coils or from wires extracted from a finished rope, straightened without damage and measured for diameter in two directions. The tensile test gives breaking force and tensile strength relative to the nominal cross-section; torsion tests twist a gauge length until fracture and count the turns; reverse bend tests flex the wire over defined radii until it breaks and count the bends. Coated wires are wrapped round a mandrel to check for cracking or flaking and the zinc mass per unit area is determined by stripping. The number of wires per cast or coil, the acceptance criteria and the grade limits come from the relevant product part and from the rope standard that ordered the test.

    What the report states

    The report lists per wire the diameter, tensile strength in N/mm² against the grade band, the number of torsions and reverse bends against the minimum for that diameter and grade, the wrapping test result and the coating mass in g/m². Non-conforming wires are identified so that the rope manufacturer can assess the effect on the rope's minimum breaking force and on its designation.

    Where the result is required

    Rope manufacturers verify incoming wire and the wires of finished ropes against EN 10264 as part of production control under EN 12385-1 and EN 12385-4. Rope users, crane and hoist manufacturers and inspection engineers request wire tests when ropes are qualified, when a failed rope is investigated or when a termination test to EN 13411-3 needs the wire grade confirmed. The results support the rope manufacturer's certificate and the technical file for lifting accessories.

    What we assess

    • tensile strength, torsion, coating

    Products covered

    • steel wire for ropes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by a harmonised European standard are CE marked on the basis of a Declaration of Performance; other product standards support national approvals and third-party certification. Amstelfy provides the initial type testing / type testing and, where the standard is on its ISO/IEC 17065 scope, acts as the product certification body.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Part 1 always applies and gives the general requirements and test references. Part 2 covers cold drawn non-alloy wire for ropes in general applications, Part 3 round and shaped non-alloy wire for high-duty ropes such as those on cranes and mining hoists, and Part 4 stainless steel wire. The order should state the part, diameter, grade and finish.

    High tensile strength alone does not guarantee that a wire survives stranding, spooling and running over sheaves. Torsion and reverse bend counts measure the ductility and surface soundness of the wire, and a wire with laps, seams or an over-hard structure will fail these tests while still meeting the strength grade.

    Yes. Wires are carefully unlaid from a rope sample, straightened and tested in the same way as coil samples. The standard recognises some reduction in properties after stranding, so the rope standard sets the acceptance criteria for extracted wires. The method is used in rope type tests and in failure investigations.

    Related standards