European Assessment Document

    EAD 340059-00-0106 - Falling rock protection kits

    Testing · NAC-037-TLCertification · NAC-026-PPSETA route

    In short

    EAD 340059-00-0106 is the EOTA European Assessment Document for falling rock protection kits. Amstelfy Technical Solutions tests rockfall barriers against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): energy absorption capacity (MEL/SEL tests), component strength and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.

    What the EAD assesses

    EAD 340059-00-0106, derived from ETAG 027, assesses falling rock protection kits: flexible barriers made of posts, an interception structure of nets or mesh, support and connection ropes, energy-dissipating devices and the connections to the foundations. The product is assessed by what it does rather than by its parts: a concrete block of defined shape is launched into a full-scale barrier, which must stop it. The service energy level (SEL) is one third of the maximum energy level (MEL); the barrier must stop two successive SEL impacts without repair, keeping a minimum residual height after the first, and one MEL impact. The kit is then classified by energy level, by residual height category after the MEL test and by maximum elongation, with the forces transmitted to the foundations reported for anchor design.

    Assessment programme

    Three functional modules of the barrier are erected at a test site on the foundations and anchors specified by the manufacturer, at the nominal height. A block of the prescribed polyhedral shape and of the mass needed for the target energy is dropped vertically or released down an inclined track so that it strikes the centre of the middle module at not less than the minimum speed fixed by the EAD. High-speed cameras record trajectory and braking distance, and load cells in anchor ropes and foundations record forces. The SEL test is two impacts at one third of the MEL without intervention between them; the MEL test is one impact at full energy. Component tests on ropes, nets, posts and dissipators support the full-scale results.

    What the report states

    The report documents block mass, velocity and energy at impact, whether the block was stopped, the maximum elongation of the barrier, the residual height after each impact as a percentage of the nominal height, the forces in each anchor and support rope against time, and the damage to posts, nets and dissipators. The TAB classifies the kit by energy level class and residual height category and lists elongation and anchor forces in the ETA.

    Where the result is required

    Rockfall barriers with an ETA are specified by road, railway and infrastructure authorities and by geotechnical designers, who match the design block energy to the energy level class and the available space to the elongation, and who size the anchors from the reported forces. The kit is CE marked under the AVCP system stated in the EAD. Mesh and net products used as interception structures are assessed separately under EAD 230008 and EAD 230004; those tests do not replace the full-scale impact test of the kit.

    What we assess

    • energy absorption capacity (MEL/SEL tests)
    • component strength
    • durability

    Products covered

    • rockfall barriers

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030Yes
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    No. ETAs are issued by Technical Assessment Bodies designated under the CPR. Amstelfy carries out the assessment tests in its accredited laboratory, prepares the test reports to the EAD's clause structure and coordinates the test plan with the TAB of your choice.

    The MEL test is a single impact at the maximum energy the kit claims; the block must be stopped, and the residual height afterwards places the kit in a residual height category. The SEL test is two impacts at one third of the MEL without maintenance between them; the barrier must stop both and keep a minimum residual height after the first, showing that it can take repeated service events.

    The EAD defines classes from 0 to 8 by the MEL energy, starting at 100 kJ and rising to above 4 500 kJ for the highest class, with the SEL set at one third of each MEL. The kit is tested at the energy of the class it claims and is classified at that level; the block mass and speed are chosen to deliver that energy at impact.

    No. The EAD requires at least three functional modules at the nominal height, so that the central module is restrained by its neighbours as it would be on site, and the impact must hit the middle module. Component tests on ropes, nets and dissipators are part of the file but cannot replace the full-scale impact; they serve factory production control and the durability assessment.

    Related standards