EAD 340059-00-0106 is the EOTA European Assessment Document for falling rock protection kits. Amstelfy Technical Solutions tests rockfall barriers against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): energy absorption capacity (MEL/SEL tests), component strength and durability. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 340059-00-0106, derived from ETAG 027, assesses falling rock protection kits: flexible barriers made of posts, an interception structure of nets or mesh, support and connection ropes, energy-dissipating devices and the connections to the foundations. The product is assessed by what it does rather than by its parts: a concrete block of defined shape is launched into a full-scale barrier, which must stop it. The service energy level (SEL) is one third of the maximum energy level (MEL); the barrier must stop two successive SEL impacts without repair, keeping a minimum residual height after the first, and one MEL impact. The kit is then classified by energy level, by residual height category after the MEL test and by maximum elongation, with the forces transmitted to the foundations reported for anchor design.
Assessment programme
Three functional modules of the barrier are erected at a test site on the foundations and anchors specified by the manufacturer, at the nominal height. A block of the prescribed polyhedral shape and of the mass needed for the target energy is dropped vertically or released down an inclined track so that it strikes the centre of the middle module at not less than the minimum speed fixed by the EAD. High-speed cameras record trajectory and braking distance, and load cells in anchor ropes and foundations record forces. The SEL test is two impacts at one third of the MEL without intervention between them; the MEL test is one impact at full energy. Component tests on ropes, nets, posts and dissipators support the full-scale results.
What the report states
The report documents block mass, velocity and energy at impact, whether the block was stopped, the maximum elongation of the barrier, the residual height after each impact as a percentage of the nominal height, the forces in each anchor and support rope against time, and the damage to posts, nets and dissipators. The TAB classifies the kit by energy level class and residual height category and lists elongation and anchor forces in the ETA.
Where the result is required
Rockfall barriers with an ETA are specified by road, railway and infrastructure authorities and by geotechnical designers, who match the design block energy to the energy level class and the available space to the elongation, and who size the anchors from the reported forces. The kit is CE marked under the AVCP system stated in the EAD. Mesh and net products used as interception structures are assessed separately under EAD 230008 and EAD 230004; those tests do not replace the full-scale impact test of the kit.
What we assess
- energy absorption capacity (MEL/SEL tests)
- component strength
- durability
Products covered
- rockfall barriers
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 230008-00-0106 - Double twisted steel wire mesh reinforced or not with ropes
- EAD 230004-00-0106 - Wire ring mesh panels