European Assessment Document
EAD 230004-00-0106 - Wire ring mesh panels
In short
EAD 230004-00-0106 is the EOTA European Assessment Document for wire ring mesh panels. Amstelfy Technical Solutions tests ring net panels against this EAD in its ISO/IEC 17025-accredited laboratory in Amstelveen (NAC-037-TL): tensile and punch resistance and corrosion protection. The test reports follow the EAD clause structure so a Technical Assessment Body can use them directly for the European Technical Assessment; Amstelfy does not issue ETAs itself. Within its ISO/IEC 17065 scope (NAC-026-PPS) Amstelfy can also act as the product certification body for this product family.
What the EAD assesses
EAD 230004-00-0106 assesses panels of interlinked steel wire rings: each ring is formed from several windings of high-tensile wire and is linked to its neighbouring rings, typically four, giving a highly deformable net that absorbs energy by stretching and by the rings sliding against each other. Ring net panels are the interception structure of many rockfall barriers and are also used as drapery and in debris-flow barriers. The EAD assesses the tensile strength of the panel in its two directions, the resistance of the panel to a concentrated punching load together with the deformation and energy absorbed, the strength of a single ring, the tensile strength of the wire, the number of windings and the durability of the coating. Because the panel is a discrete-element structure, the test fixtures and the way the border rings are gripped are prescribed.
Assessment programme
Panels of the dimensions required by the EAD are tested in tension by connecting the border rings along two opposite edges to loading bars and pulling until the first ring fails, recording load and elongation in each direction. In the punch test a panel is fixed on all four sides in a rigid frame and a punch of the prescribed shape is driven into its centre until failure, with force and displacement recorded so that the absorbed energy can be integrated. Single rings are tested in tension. Wire samples are tested for tensile strength and elongation, windings and ring diameter are measured, and coating mass and corrosion resistance are determined by stripping and by salt-spray exposure for the claimed class.
What the report states
The report gives the tensile strength of the panel per metre in each direction with the elongation at failure, the punch force, displacement and absorbed energy, the single-ring breaking load, wire strength, number of windings, ring and panel dimensions, coating mass and the corrosion test result. The TAB states these as declared values and durability class in the ETA, which the barrier designer and the kit manufacturer then use.
Where the result is required
Ring net panels with an ETA are specified as components of falling rock protection kits under EAD 340059, as secured drapery and slope-facing systems in combination with anchors and ropes, and in flexible debris-flow and shallow-landslide barriers. The product is CE marked under the AVCP system stated in the EAD. Double-twisted hexagonal mesh for lighter applications is assessed under EAD 230008, and the wire itself is characterised with the EN 10218 and EN 10264 series.
What we assess
- tensile and punch resistance
- corrosion protection
Products covered
- ring net panels
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | Yes |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
Products covered by an EAD are placed on the EU market with a European Technical Assessment issued by a Technical Assessment Body (TAB), followed by the AVCP tasks of a Notified Body and the manufacturer's Declaration of Performance and CE marking. Amstelfy performs the assessment tests, prepares the test reports in the EAD's clause structure and coordinates the test plan with the TAB; Amstelfy does not issue ETAs.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- EAD 230008-00-0106 - Double twisted steel wire mesh reinforced or not with ropes
- EAD 340059-00-0106 - Falling rock protection kits