US qualification standard

    ASTM D3330 - Standard test method for peel adhesion of pressure-sensitive tape

    Testing · NAC-037-TL

    In short

    ASTM D3330 - Standard test method for peel adhesion of pressure-sensitive tape. Amstelfy's laboratory in Amstelveen performs this ASTM method for adhesives, tile adhesives and tapes: peel adhesion. Testing is on the ISO/IEC 17025 accreditation scope NAC-037-TL, which lets European manufacturers prepare US evaluation-report programmes without shipping samples overseas.

    What ASTM D3330 determines

    ASTM D3330/D3330M measures the force needed to remove a pressure-sensitive tape from a standard test panel, or from its own backing or liner, under controlled application and peel conditions. Pressure-sensitive adhesives bond on contact without curing, so their peel adhesion depends on how they were applied, how long they dwelled and how fast they are removed; the method fixes all three. Several test methods are defined: Method A for single-coated tapes peeled at 180 degrees from a stainless steel panel, Method F for a 90 degree peel, and Methods B to E for double-coated tapes and for adhesion to and of release liners. The result ranks tapes, supports data sheets and controls production; it is not a bond strength for design.

    Specimens, conditioning and procedure

    Test panels of the stainless steel specified by the method are cleaned with the prescribed solvents; a strip of tape of the standard width is applied adhesive side down and rolled twice in each direction with the standard rubber-covered roller, without hand pressure. After the dwell time, which the client may fix at the method's short default or at a longer period, the free end of the tape is doubled back for Method A and clamped in the moving grip while the panel sits in the fixed grip, and the tape is peeled at 300 mm/min. For Method F a 90 degree fixture is used. The force is recorded over the central portion and several specimens are tested.

    What the report states

    Peel adhesion is reported as force per unit width, in N per 100 mm or in ounce-force per inch when inch-pound units are requested, as the average over the evaluated length for each specimen and the mean of the set, with the method letter, dwell time, panel, peel angle and speed. The failure type is noted: clean removal, adhesive residue on the panel, backing tear or liner split. Values are used for data sheets and incoming inspection.

    Where the result is required

    ASTM D3330 is the reference peel method on data sheets for masking, packaging, foam-mounting, flashing and construction tapes sold in North America, and is cited by tape users in specifications for self-adhesive membranes, labels, protective films and sealing tapes. European manufacturers use it alongside EN ISO 8510 and EN 1939, the European tape method, when exporting or supplying US-based customers, and the results support ICC-ES evaluation report programmes where tape adhesion is a listed property.

    What we assess

    • peel adhesion

    Products covered

    • adhesives
    • tile adhesives
    • tapes

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028Yes
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030No

    Route to market

    US and international evaluation-report programmes (ICC-ES, IAPMO UES, ACI 318 qualification) accept data from ISO/IEC 17025-accredited laboratories. Amstelfy runs these programmes in the Netherlands so European manufacturers avoid shipping samples overseas; the evaluation report itself is issued by the evaluation service.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Yes - it is listed on the ISO/IEC 17025 testing scope NAC-037-TL.

    Method A peels a single-coated tape from the panel at 180 degrees, folding the tape back on itself; Method F peels it at 90 degrees using a fixture that keeps the tape perpendicular to the panel. Stiff or thick backings give lower apparent values at 180 degrees because of bending work, so Method F is often chosen for foam and film tapes.

    A pressure-sensitive adhesive flows into the surface roughness of the panel over time, so the contact area and the peel force rise after application. The method fixes a short standard dwell and allows a longer dwell to be reported separately; data sheets often quote both. Specimens are also kept in the standard atmosphere so that temperature does not alter the flow.

    Yes. The standard panel gives comparable data between laboratories, but a client can ask for the same procedure on its own substrate, for example a coated metal, a plastic film, a membrane or a board. The report then identifies the substrate and its preparation, and the result is reported as a modified method rather than as a standard D3330 value.

    Related standards

    All Rubber, elastomers, sealants & adhesives testing