Certification scheme
EPD process certification (International EPD System GPI 5.0.1) - Certification of an organisation's EPD process
In short
Certification of an organisation's EPD process. Amstelfy Technical Solutions is accredited to ISO/IEC 17065:2012 (NAC-026-PPS) for manufacturers publishing multiple EPDs: EPD development and management system, competence to produce, control and publish EPDs under the GPI and PCRs and surveillance audits.
What is certified
The General Programme Instructions of the International EPD System allow an organisation that publishes many EPDs to have its EPD process certified instead of submitting every declaration to individual third-party verification. The object of certification is the process: how product data are collected, how the LCA model is built and maintained, how PCR and complementary PCR requirements are applied, how EPD documents are produced under EN 15804+A2, ISO 21930 where applicable and EN 15942, how the internal verifier checks each declaration independently of the practitioner, how competence is maintained and how changes in standards, datasets and production are handled. The certification body, accredited to ISO/IEC 17065 for this scheme, audits the process against ISO 14025, ISO 14040 and ISO 14044 and the programme requirements, certifies it, and keeps it under surveillance. EPDs produced under the certified process are registered with the programme operator on the strength of the internal verification and the certificate.
Certification steps
The applicant documents its EPD process: procedures, roles, competence records for LCA practitioners and internal verifiers, document control, the list of PCRs and tools in use, and a register of published EPDs. The certification body reviews the documentation, then audits on site or remotely, examining a sample of EPDs with their background reports and the internal verification records, tracing data from production records into the model and out to the published indicators, and checking that nonconformities found internally were closed. Findings are raised and corrective actions assessed before the certificate is granted. Surveillance audits follow at the intervals the scheme prescribes, each sampling new or updated EPDs, and the certificate is renewed by a recertification audit. The organisation defines the product groups, sites and PCRs the process covers.
What the report states
The organisation receives an audit report and, on a positive decision, a certificate of its EPD process naming the scope of products, sites and PCRs and the programme under which it applies, listed by the programme operator. Each EPD then published under the process carries the reference to the certified process and the internal verifier. Suspension or withdrawal of the certificate ends that route and returns the organisation to individual verification.
Where the result is required
Process certification suits producers with large product ranges or many plants, such as ready-mixed concrete and precast groups, cement and aggregate companies, insulation and plasterboard manufacturers, steel and rebar mills and ceramic producers, who issue dozens of EPDs a year or regenerate them per plant and recipe. It is used together with EPD tools and digital EPD generation, and it is recognised by the International EPD System within the construction scope of the accreditation.
What we assess
- EPD development and management system
- competence to produce, control and publish EPDs under the GPI and PCRs
- surveillance audits
Products covered
- manufacturers publishing multiple EPDs
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | No |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | Yes |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | No |
Route to market
EPD process certification lets a manufacturer publish EPDs under its certified process in line with the programme rules, with surveillance audits by Amstelfy.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.