Verification scope

    ISO 14025 / EN 15804+A2 (EPD verification) - Third-party verification of Environmental Product Declarations - construction products

    Verification · NAC-006-VV

    In short

    Third-party verification of Environmental Product Declarations - construction products. Amstelfy Technical Solutions is an ISO/IEC 17029:2019-accredited validation and verification body (NAC-006-VV). Scope: EPDs of construction products and construction services under The International EPD System (GPI) and applicable PCR/c-PCR; what is assessed: conformity of the LCA and EPD with ISO 14025, EN 15804+A2, the GPI and the PCR, data quality, system boundaries, allocation, scenarios and EPD content and format (EN 15942 where required).

    What is verified

    An Environmental Product Declaration is a Type III declaration under ISO 14025: quantified life-cycle data for a product, produced under a programme and checked by an independent verifier before publication. For construction products the core rules are EN 15804+A2, which fixes the declared or functional unit, the module structure A1–A3, A4–A5, B1–B7, C1–C4 and D, the cut-off and allocation rules, the indicator set with its characterisation factors, and the content of the declaration. Verification confirms that the LCA study and the EPD text conform to these rules, to the General Programme Instructions of the International EPD System and to the applicable PCR and complementary PCR, that the data are plausible and representative, and that the results are reproducible from the underlying model. What is verified is conformity and plausibility, not the environmental merit of the product. The accredited scope covers construction and building materials only.

    Verification steps

    The verifier receives the LCA background report, the model or its documentation, the data collection sheets and the draft EPD. Checks follow a plan: product definition and declared unit; system boundary and the modules included, with the justification for any omission; primary data for the manufacturer's own processes and the representativeness of secondary datasets; mass and energy balances; allocation of co-products and recycling flows and the treatment of biogenic carbon; scenarios for transport, installation, use and end of life; the calculation of the indicator set with the prescribed characterisation factors; and the completeness and wording of the EPD against EN 15804 and, where required, the EN 15942 communication format. Findings are issued in writing, the practitioner corrects the model or text, and the verifier confirms the closure before signing the verification statement for registration with the programme operator.

    What the verification statement covers

    The client receives a verification report listing the checks performed, the findings and their resolution, and a signed verification statement naming the verifier, the standards and the PCR versions, which the programme operator requires for publication. The verified EPD carries the verifier identification and its validity period. Findings that cannot be resolved are reported as such and the EPD is not released for registration.

    Where the result is required

    Verified EPDs are required for registration and publication in the International EPD System and are read by designers, procurement and building assessment schemes such as BREEAM, DGNB and LEED, by national building regulations that use product-level carbon data, and by manufacturers' own corporate reporting. Insulation, concrete and cement, steel and reinforcement, FRP products, membranes, mortars and cladding are typical subjects within the construction scope. EPDs from other programme operators are verified where that operator accepts an ISO/IEC 17029-accredited body.

    What we assess

    • conformity of the LCA and EPD with ISO 14025, EN 15804+A2, the GPI and the PCR
    • data quality, system boundaries, allocation, scenarios
    • EPD content and format (EN 15942 where required)

    Products covered

    • EPDs of construction products and construction services under The International EPD System (GPI) and applicable PCR/c-PCR

    Accreditation status

    ActivityStandardAccreditationValidityOn scope
    TestingISO/IEC 17025:2017NAC-037-TLvalid until 2 December 2028No
    Product certificationISO/IEC 17065:2012NAC-026-PPSvalid until 31 January 2030No
    Validation & verificationISO/IEC 17029:2019NAC-006-VVvalid until 31 January 2030Yes

    Route to market

    Verified EPDs and GHG statements are published by the programme operator or used in corporate reporting. Amstelfy verifies; it does not prepare the LCA or the GHG inventory it verifies.

    How it works

    1. 1

      Send the standard number, product description and intended use

    2. 2

      We confirm the applicable test series, sample quantities and timeline

    3. 3

      Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)

    4. 4

      You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.

    Frequently asked questions

    Amstelfy is listed as an Accredited Certification Body by The International EPD System and is a member of ECO Platform. Ask us before starting if your target programme is a different one.

    The LCA background report written for verification, with the data collection sheets, the mass and energy balances, the dataset list with versions, the allocation and scenario justifications and the results per module; access to the model or exported calculation files; production and purchasing records that support the primary data; and the PCR and complementary PCR versions used. Missing items are the most common cause of delay in a verification.

    Modules A1 to A3, C1 to C4 and D are the default minimum, with the exemptions the standard allows for products that cannot be separated from the works at end of life or that meet the other listed conditions. Modules A4, A5 and B1 to B7 are declared when the PCR requires them or the manufacturer chooses to, with scenarios that the verifier checks for consistency.

    The tool itself and its background data have been verified once, so the verifier concentrates on the product-specific inputs, the correct use of the tool within its validated scope, the plausibility of the results against the reference products and the EPD text. The programme instructions set out which checks remain per EPD; they are fewer but not absent.

    Related standards

    All EPD & greenhouse-gas verification (ISO/IEC 17029) testing