Verification scope
ISO 14025 / EN 15804+A2 (EPD verification) - Third-party verification of Environmental Product Declarations - construction products
In short
Third-party verification of Environmental Product Declarations - construction products. Amstelfy Technical Solutions is an ISO/IEC 17029:2019-accredited validation and verification body (NAC-006-VV). Scope: EPDs of construction products and construction services under The International EPD System (GPI) and applicable PCR/c-PCR; what is assessed: conformity of the LCA and EPD with ISO 14025, EN 15804+A2, the GPI and the PCR, data quality, system boundaries, allocation, scenarios and EPD content and format (EN 15942 where required).
What is verified
An Environmental Product Declaration is a Type III declaration under ISO 14025: quantified life-cycle data for a product, produced under a programme and checked by an independent verifier before publication. For construction products the core rules are EN 15804+A2, which fixes the declared or functional unit, the module structure A1–A3, A4–A5, B1–B7, C1–C4 and D, the cut-off and allocation rules, the indicator set with its characterisation factors, and the content of the declaration. Verification confirms that the LCA study and the EPD text conform to these rules, to the General Programme Instructions of the International EPD System and to the applicable PCR and complementary PCR, that the data are plausible and representative, and that the results are reproducible from the underlying model. What is verified is conformity and plausibility, not the environmental merit of the product. The accredited scope covers construction and building materials only.
Verification steps
The verifier receives the LCA background report, the model or its documentation, the data collection sheets and the draft EPD. Checks follow a plan: product definition and declared unit; system boundary and the modules included, with the justification for any omission; primary data for the manufacturer's own processes and the representativeness of secondary datasets; mass and energy balances; allocation of co-products and recycling flows and the treatment of biogenic carbon; scenarios for transport, installation, use and end of life; the calculation of the indicator set with the prescribed characterisation factors; and the completeness and wording of the EPD against EN 15804 and, where required, the EN 15942 communication format. Findings are issued in writing, the practitioner corrects the model or text, and the verifier confirms the closure before signing the verification statement for registration with the programme operator.
What the verification statement covers
The client receives a verification report listing the checks performed, the findings and their resolution, and a signed verification statement naming the verifier, the standards and the PCR versions, which the programme operator requires for publication. The verified EPD carries the verifier identification and its validity period. Findings that cannot be resolved are reported as such and the EPD is not released for registration.
Where the result is required
Verified EPDs are required for registration and publication in the International EPD System and are read by designers, procurement and building assessment schemes such as BREEAM, DGNB and LEED, by national building regulations that use product-level carbon data, and by manufacturers' own corporate reporting. Insulation, concrete and cement, steel and reinforcement, FRP products, membranes, mortars and cladding are typical subjects within the construction scope. EPDs from other programme operators are verified where that operator accepts an ISO/IEC 17029-accredited body.
What we assess
- conformity of the LCA and EPD with ISO 14025, EN 15804+A2, the GPI and the PCR
- data quality, system boundaries, allocation, scenarios
- EPD content and format (EN 15942 where required)
Products covered
- EPDs of construction products and construction services under The International EPD System (GPI) and applicable PCR/c-PCR
Accreditation status
| Activity | Standard | Accreditation | Validity | On scope |
|---|---|---|---|---|
| Testing | ISO/IEC 17025:2017 | NAC-037-TL | valid until 2 December 2028 | No |
| Product certification | ISO/IEC 17065:2012 | NAC-026-PPS | valid until 31 January 2030 | No |
| Validation & verification | ISO/IEC 17029:2019 | NAC-006-VV | valid until 31 January 2030 | Yes |
Route to market
Verified EPDs and GHG statements are published by the programme operator or used in corporate reporting. Amstelfy verifies; it does not prepare the LCA or the GHG inventory it verifies.
How it works
1
Send the standard number, product description and intended use
2
We confirm the applicable test series, sample quantities and timeline
3
Samples are delivered to Veilmeesterweg 20, 1187 ZW Amstelveen (Mon-Fri 09:00-17:00)
4
You receive the report in English, written for the TAB, Notified Body, evaluation service or programme operator.
Frequently asked questions
Related standards
- ISO 14064-1 / ISO 14064-3 (organisation-level GHG verification) - Verification of greenhouse-gas statements at organisation level
- ISO 14064-2 / ISO 14064-3 (project-level GHG validation and verification) - Validation and verification of GHG emission reduction and removal projects